24 Quick start-up

Operating instructions

The solar pump inverter is developed using the ACS355 firmware. Install the inverter as
defined in sections
Mechanical
cables. Before operating the inverter, set the required parameters defined in the following
steps.
Step
Action
1
Install the solar pump inverter.
2
Connect the AC/DC input and motor cables
and the control cables.
3
Enter the commissioning data parameters in
99 START-UP
4
Set the basic application data using either
the control panel or the Drive window light
PC tool application:
Group
10 START/STOP/DIR
Group
11 REFERENCE SELECT
Group
20 LIMITS
Group
21 START/STOP
Group
60 PUMP CONTROL
Group
61 FLOW CALCULATION
Group
99 START-UP DATA
5
Monitor the inverter signals in Group
OPERATING
If the inverter power rating matches the motor power rating, the inverter is ready to run. If
any parameter tuning such as acceleration and deceleration times, maximum and
minimum speeds, and so on is required, see ACS355 User's manual
(3AUA0000066143 [English]).
installation,
DATA.
DATA.
Installing power
cables, and
Additional information
See section Mechanical installation in
ACS355 User's manual
(3AUA0000066143 [English]).
See section Connecting the power cables
and Connecting the control cables in
ACS355 User's manual
(3AUA0000066143 [English]).
See section 99 START-UP DATA in
ACS355 User's manual
(3AUA0000066143 [English]).
See section Control panels in ACS355
User's manual
(3AUA0000066143 [English]).
The inverter is supported by version 2.91
or later of the Drive Window Light 2 PC
tool which includes a graphical Sequence
programming tool.
01
See section Actual Signals in ACS355
User's manual
(3AUA0000066143 [English]).
Installing control