ABB ACS355 Manual page 47

Solar pump inverter (+n827)
Hide thumbs Also See for ACS355:
Table of Contents

Advertisement

All parameters
No.
Name/
Value
KEYPAD (RNC)
KEYPAD (NC)
ODVA HZ REF
SOLAR
1105
REF1MAX
0.0...500.0 Hz/
0...30000 rpm
16 SYSTEM
CONTROLS
1604
FAULT RESET
SEL
KEYPAD
DI1
DI2
DI3
DI4
DI5
Description
Defines the control panel as reference source. The
stop command resets the reference to zero (R
represents reset).
Note: The reference value is not saved if the control
source is changed (EXT1 to EXT2 or EXT2 to EXT2).
Defines the control panel as reference source. The
stop command does not reset the reference to zero.
The reference is stored.
Note: The reference is not saved if the control source
is changed (EXT1 to EXT2 or EXT2 to EXT2).
Defines the fieldbus interface with ODVA AC/DC
profile and reference values in Hz. In the ODVA profile,
the unit for SpeedRef if rpm. The Speed (Frequency)
reference can be given also in Hz instead of rpm.
SOLAR mode.
The inverter takes the speed reference calculation
from MPPT.
Defines the maximum value for external reference
REF1. This value corresponds to the maximum setting
of the used source signal. For solar operation this
signal limits the maximum speed reference calculated
internally.
Maximum value in Hz/rpm.
9904
If
MOTOR CTRL MODE
FREQ, the unit is Hz.
Parameter view, Run enable, parameter lock, etc.
Selects the source for the fault reset signal. The signal
resets the drive after a fault trip if the cause of the fault
no longer exists.
Fault reset only from the control panel
Reset through digital input DI1 (reset on the rising
edge of DI1) or from the control panel
See selection DI1.
See selection DI1.
See selection DI1.
See selection DI1.
Actual signals and parameters 47
is set as SCALAR:
Def/ FbEq
20
21
36
37
50.0 Hz/
3000 rpm
1 = 0.1 Hz/
1 rpm
DI2
0
1
2
3
4
5