ABB ACS355 Manual page 46

Solar pump inverter (+n827)
Hide thumbs Also See for ACS355:
Table of Contents

Advertisement

46 Actual signals and parameters
All parameters
No.
Name/
Value
DI3U,4D
COMM
COMM+AI1
COMM*+AI1
DI3U, 4D(R)
DI3U, 4D(NC)
AI1+AI2
AI1*AI2
AI1-AI2
AI1/AI2
Description
Digital input DI3: Reference increase.
Digital input DI4: Reference decrease.
The program stores the active speed reference (not
reset by a stop command). When the drive is
restarted, the motor ramps up at the selected
acceleration rate to the stored reference.
Parameter 2205 ACCELER TIME 2 defines the rate of
reference change.
Fieldbus reference REF1.
Summation of fieldbus reference REF1 and analog
input AI. See section Reference selection and
correction in ACS355 User's manual
(3AUA0000066143[English]).
Multiplication of fieldbus reference REF1 and analog
input AI. See section Reference selection and
correction in ACS355 User's manual
(3AUA0000066143[English]).
• Digital input DI3: Reference increase.
• Digital input DI4: Reference decrease.
Stop command resets the reference to zero.
Parameter 2205 ACCELER TIME 2 defines the rate of
the reference change.
• Digital input DI3: Reference increase.
• Digital input DI4: Reference decrease.
Program stores the active speed reference (not reset
by a stop command). When you restart the inverter,
the motor ramps up at the selected acceleration rate to
the stored reference.
Parameter 2205 ACCELER TIME 2 defines the rate of
the reference change.
Calculated reference using the equation:
( )
( ) 50
REF
=
AI1 %
+
AI2 %
Calculated reference using the equation:
( )
×
( )
REF
=
AI1 %
(AI2 %
Calculated reference using the equation:
( )
( ) AI2
REF
=
AI1 %
+
50 %
Calculated reference using the equation:
( )
×
( )
REF
AI1 %
(50 %
=
( )
%
(
)
50%)
( )
%
(
)
AI2(%)
Def/ FbEq
6
8
9
10
11
12
14
15
16
17