How the Rinnai Linear models start
Ignition
sequence:
1. When the On/Off button is pressed, the infra-red receiver window will pulse green.
2. The combustion fan will start several seconds before the fire ignites, to purge the combustion
chamber before the gas flows.
3. The ignition sparker will operate, and as soon as a spark is sensed gas will flow to the pilot
burner, and then to the main burner.
4. When the main burner establishes a flame, the heater will automatically modulate between the
burner settings to achieve and maintain the default set temperature of 22 °C
Do not unplug or turn off the mains power supply to the fire as this will stop the convection fan
from cooling down the unit. The convection fan operates for several minutes after the fire has been
turned off.
Power cut or power disruption
If the power is disrupted while the Linear is operating, once the
power has been restored, the fire will go into power failure mode,
and 00 (mains power failure) will appear on your smart device.
To reset the fire, press the ON/OFF button on the control panel,
remote control, or on the app, twice, to turn the fire back on.
Position of your Rinnai Linear on a wall
If installing the Linear up the wall in an elevated position, air from the convection fan, depending
on the room configuration, could create draughts. This needs to be factored when determining the
location of the fire.
Wall surface above the fire
The temperature of the wall surface directly above the appliance may get warm and discolour
paint finishes or distort wall coverings. For durability of surfaces, please contact the manufacturer
for their specification. The finish needs to be able to withstand temperatures of up to 65 °C above
ambient.
On initial start-up (no additional buttons pressed), the Linear modulates the flame and heat output to try and maintain
1
the default temperature setting of 22 °C. If the room temperature starts to climb above 22 °C the Linear will modulate
to its lowest flame and fan setting, but will not turn off. Depending on the size of the room this could mean the room
temperature could steadily rise.
.
1
Fault Code and Fix
Probable Cause
00
Mains power failure.
Description
When power failure is sensed
operation stops.
Action
Reset heater, press the On/Off
button at the fireplace twice.