Accessories; Load Connections - KEPCO BOP 1KW-MG Series Quick Start Manual

Hide thumbs Also See for BOP 1KW-MG Series:
Table of Contents

Advertisement

VII — ACCESSORIES.
ITEM
Line Cord (250V, 20A)
Line Cord (250V, 20A)
Mating Connector, Trigger
IEEE 1118 (BITBUS)
Mating connector
IEEE 488 Cable, (1 meter long) For MG models only. Connects BOP power supply to GPIB bus.
IEEE 488 Cable, (2 meter long) For MG models only. Connects BOP power supply to GPIB bus.
IEEE 488 Cable, (4 meter
longs)
Interconnection Kits for parallel/
series configurations.
RS 232 Cable Kit
RS 232 Adapter (Male pins)
RS 232 Adapter (Female pins)
15-pin DSUB Connector
IDC 6-pin connector
IDC 8-pin plug
Slides
Heat Sink
Output Terminal Cover

LOAD CONNECTIONS.

quire wires that are properly rated for the nominal output
current of the unit. Connect the load to the OUTPUT
and COMMON power terminals on the rear panel (see
Figure 3). OUT S and COM S terminal of the Monitor
and Sensing Terminal block are for connection of
remote sensing leads (after removing the factory-
installed local sensing links).
KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102
062119
See Table 5.
TABLE 5. ACCESSORIES
Provides connection to a-c mains via Nema 6-20P connector.
Provides connection to a-c mains via Nema L6-20P locking type connector.
Mates with Trigger port.
Allows connection to IEEE 1118 (BITBUS) port.
For MG models only. Connects BOP power supply to GPIB bus.
Cables required to connect multiple BOP models in parallel, series, or paral-
lel/series configurations.
Contains RJ11 to RJ45 Patch cord, RJ 45 Patch cord, two RS 232 adapters,
one with male pins to connect to DTE equipment and one with female pins to
connect to a PC (personal computer), two RS 232 Loop Back test Connec-
tors (one 6-pin and one 8-pin) to test RS 232 communication and aid in iso-
lating RS 232 communication problems.
Allows RS 232 port to be connected to DTE equipment. (Supplied in KIT
219-0436.)
Allows RS 232 port to be connected to a PC (personal computer). (Supplied
in KIT 219-0436.)
Mating connector for Analog input connector A2A5J6
Mating connector for RS-232 PORT, connector A1J5 and PROTECTION
EXT. PORT, connector A2A5J7
Mating connector for PAR/SER PROTECT PORT (IN and OUT) connectors.
Allows easy withdrawal of unit from rack (see Figure 1). (Model CS 04
includes slides, brackets, all mounting hardware and installation instruc-
tions.)
Provides adequate cooling for calibration sense resistors.
Protects against inadvertent contact with output and barrier strip terminals
Power
connections
re-
www.kepcopower.com   email: hq@kepcopower.com
FUNCTION
Dsub 15 pin hood
Dsub 15 pin male
NOTE: Output Sense lines must be connected for
proper operation, either locally, or at the load
(remote). Also use OUT S and COM S to monitor volt-
age at the load using external equipment such as a
DVM, oscilloscope, etc. Use OUT MON and COM
MON to monitor voltage at the BOP output. Use twisted
wire pairs or wires that are tied together for both output
power and output sensing connections.
228-1692 REV 9
PART NUMBER
118-1087
118-1088
142-0527 (Kepco)
SP2501 (CUI Stack)
142-0485 (Kepco)
KMDLA-5P (Kycon Inc.)
SNC 488-1
SNC 488-2
SNC 488-4
See Operator's Manual.
KIT 219-0436
142-0487
(L-COM RA098M)
142-0506
(L-COM RA098F)
108-0374
(Tyco-Amp 207470-1)
142-0449
(Amphenol 17S-DA15P)
142-0536
(Amphenol 5-555176-3)
142-0535
(Amphenol 5-555176-3)
CS 04
136-0451
129-0423
5

Hide quick links:

Advertisement

Table of Contents
loading