VIII — OPERATION.
Additional features covered in the Operator Manual
are: operation via the LAN interface or analog signals
and setting coarse/fine adjustment preference of the
VOLTAGE and CURRENT controls. An Installation/
Operation Summary is also included in the Operator
Manual. The Operator Manual also covers the GPIB,
Ethernet and RS 232 interfaces, including the use of
the drivers downloadable from:
www.kepcopower.com/drivers/drivers-dl3.htm#bop1k.

TURNING THE POWER SUPPLY ON.

!
DO NOT repeatedly toggle the cir-
cuit breaker/switch as this may
damage the unit.
Set POWER ON/OFF circuit breaker/switch on front
panel to ON. If actuator does not lock when released,
wait a few seconds before trying again. The circuit
breaker is "trip-free" design; if overload exists, contacts
cannot be held closed by actuator.
• When the power supply is turned on, it per-
forms a brief self-test that includes testing the
three processors (analog, interface and dis-
play), then displays the power-up screen (see
Figure 5). If an error is detected, the FAULT
indicator will light, information about the error
will be briefly displayed on the LCD.
• If the unit powers up in REMOTE mode, press
!
to set the unit to LOCAL mode.
• If the display is not viewable, press
The display will cycle through the range of
contrast settings. Press
the preferred contrast.

ACCESSING THE MENUS.

screen, pressing the Function keys indicated on the
LCD opens the associated menu. The menu opened
may list submenus that may be opened either directly
by pressing the associated Function keys, or by high-
lighting an item on the list and pressing the View/Mod-
ify function key. Menus and submenus will display a list
of parameters, with the top one highlighted. The func-
tion key assignments can vary, but generally offer the
following choices:
KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102
062119
CAUTION:
#
#
again to lock in
From the power-up
www.kepcopower.com   email: hq@kepcopower.com
!
allows the highlighted parameter to be
viewed or modified. After changing the param-
eter, the following choices are available:
SAVE or ENTER to save the change,
EXIT to abort the change and exit to the previ-
ous menu.
@
- RESTORE DEFAULT restores factory
defaults for the parameters displayed (except
for GPIB address). The factory defaults may
be saved as power-up defaults by pressing
$
.
#
- The function varies, depending on the
menu. In most cases
change without applying the modified setting.
From the power-up screen
adjust contrast. In the Revisions/TEST sub-
menu of the General Setup Menu,
to execute a test.
$
- SAVE FOR POWER-UP Saves the con-
figuration shown as a power-up setting so the
changes will not be lost when the unit is
turned off.
%
- APPLY EXIT applies the current
(changed) setting without saving for power-up
and exits to the previous menu or to the
power-up screen, EXIT leaves the current
menu without saving or applying changes.
The menu structure is as follows (NOTE: BOLD = Fac-
tory Default):
twice.
Power-up Screen (Power up menu)
228-1692 REV 9
#
is used to abort a
#
!
- Save/Recall
Saved Setups: Recall one of 99 saved set-
ups.
Saved Setup Details: Mode (voltage/
current/External), main channel refer-
ence (internal/external/external refer-
ence level) and setting, Protection Type
(internal/external/LesserLimit) and set-
ting(s), output status (on/off)
@
- Waveform
Saved Waveforms: Choose one of 16
saved waveforms.
New Waveform Settings: Name (max.
10 characters), mode (voltage/current)
No. of cycles, +Protect, -Protect)
First segment: type (Square/ +ramp
/-ramp/triangle/sine/level),
Frequency, PtoP Amplitude, Offset
Edit Waveform: Name, no. of cycles,
+protect, -protect, segment list, mode
Segment Details: Type ((Square/
+ramp/-ramp/triangle/sine/level/
slope/trigger), frequency or period,
amplitude, offset, start/stop angle
$
-
%
-
is used to
#
is used