In addition, these components are required to operate a High Frequency Drive:
● Active Line Module in the booksize or chassis format in conjunction with an Active
Interface Module
● Control Unit
● Voltage Protection Module (for synchronous motors)
● Braking Module (for synchronous motors)
● Control Supply Module (for synchronous motors)
● 24 V power supply, for example SITOP
Table 4- 1
HF module package Liquid Cooled
Article No.
6SL3125-1UE32-2AD0
The HF module package includes the parts listed in the table.
Table 4- 2
Scope of supply
Designation
HF Motor Module
HF Choke Module
HF Damping Module
3-phase busbar connector for transverse busbar connections
Equipotential bonding bar
Shield connection plate
Terminal Kit
High Frequency Drive
System Manual, (SH2), 04/2015, 6SL3097-4AH10-0BP3
Dimensions (W x H x D)
[mm]
750 x 622 x 226
Technical data
16 kHz, 400 V, 225 A
6SL3125-1UE32-2AA0
6SL3125-2UE32-2AA0
6SL3125-3UE32-2AA0
High Frequency Modules
4.1 Introduction
Cooling
Liquid cooling
Article No.
Quantity
1
1
1
2
1
1
1
33