Siemens SINAMICS S120 System Manual page 152

High frequency drive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Configuring
10.1 Features
Calculating the maximum speed for synchronous and induction motors
Table 10- 2
Overview of parameters to calculate the speed
Parameter
Meaning
r0297
Overvoltage threshold DC link 820 V
p0233
Filter inductance, 0.036 mH
p0234
Filter capacitance [µF]
16 kHz
32 kHz
p0304
Rated motor voltage [V]
p0310
Rated motor frequency [Hz]
p0311
Rated motor speed [rpm]
p0314
Motor pole pair number
Synchronous motor:
Induction motor:
p0315
Motor pole pair width [mm]
p0316
Motor torque constant, rotary [Nm/A]
Motor force constant, linear [N/A]
p0317
Motor voltage constant [V]
p0348
Speed at the start of field weakening [rpm] for V
p0353
Motor series inductance [mH]
p0356
Motor stator leakage inductance [mH]
p0358
Motor rotor leakage inductance [mH]
p0360
Motor magnetizing inductance [mH]
Motor leakage inductance / armature inductance (incl. series inductance, if applicable)
Synchronous motor:
Induction motor:
The pole pair number for induction motors corresponds to the numbers in front of the decimal place of the calculated
1)
parameter.
The maximum motor speed for synchronous and induction motors can be calculated with the
following formulas. Here, the parameters should be used in the units listed in the tables
above.
152
Without additional capacitance
11.9 µF
2.72 µF
On the rating plate
p0314 = (p0310 [Hz] • 60) / p0311 [rpm]
= 600 V (425 V
dc
L_motor [mH] = p0356 + p0353
L_motor [mH] = p0356 + p0360 - p0360
With additional capacitance
15.2 µF
3.4 µF
1)
/ p0317 · 1000 rpm)
rms
/ (p0360 + p0358) + p0353
2
System Manual, (SH2), 04/2015, 6SL3097-4AH10-0BP3
High Frequency Drive