Download Print this page
UEi DL479 Instruction Manual

UEi DL479 Instruction Manual

Ac 600a trms hvac/r clamp meter
Hide thumbs Also See for DL479:

Advertisement

Quick Links

AC 600A TRMS HVAC/R
Clamp Meter
INSTRUCTION MANUAL
ENGLISH
600V
CAT IV
1000V
CAT III
Measurement
Category
II
III
IV
The DL479 is warranted to be free from defects in materials and workmanship
for a period of two years from the date of purchase. If within the warranty
period your instrument should become inoperative from such defects, the unit
will be repaired or replaced at UEi's option. This warranty covers normal use
and does not cover damage which occurs in shipment or failure which results
from alteration, tampering, accident, misuse, abuse, neglect or improper
maintenance. Batteries and consequential damage resulting from failed
batteries are not covered by warranty.
Any implied warranties, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are limited to the express
warranty. UEi shall not be liable for loss of use of the instrument or other
incidental or consequential damages, expenses, or economic loss, or for any
claim or claims for such damage, expenses or economic loss.
A purchase receipt or other proof of original purchase date will be required
before warranty repairs will be rendered. Instruments out of warranty will be
repaired (when repairable) for a service charge.
This warranty gives you specific legal rights. You may also have other rights,
which vary from state to state.
CAUTION: This symbol indicates that equipment and its accessories
shall be subject to separate collection and correct disposal.
Periodically clean your meter's case using a damp cloth. DO NOT use abrasive,
flammable liquids, cleaning solvents, or strong detergents as they may damage the
finish, impair safety, or affect the reliability of the structural components.
Remove the batteries when instrument is not in use for a prolonged period of time.
Do not expose to high temperatures or humidity. After a period of storage in extreme
conditions exceeding the limits mentioned in the General Specifications section, allow
the instrument to return to normal operating conditions before using it.
Copyright © 2016 UEi. All Rights Reserved.
CATEGORY DEFINITIONS
Short-Circuit
(typical) kA
a
< 10
Circuits connected to mains socket
outlets and similar points in the MAINS
installation
< 50
Mains distributions parts of the building
> 50
Source of the mains installation in the
building
WARRANTY
DISPOSAL
CLEANING
STORAGE
DL479
Visit us at www.TestEquipmentDepot.com
True RMS
MAX/MIN
Hz / Duty
Location in the
building installation
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431

Advertisement

loading

Summary of Contents for UEi DL479

  • Page 1 Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss.
  • Page 2: General Specifications

    FEATURES • True RMS • Backlight • 600A AC • Worklight • 750V AC/600V DC • Audible voltage indicator • Resistance 60MΩ • Low battery indicator • Capacitance 2000µF • Auto power off • Temperature -31˚ to 752˚F (-35˚ to 400˚C) •...
  • Page 3: Battery Replacement

    OVERVIEW True RMS MAX/MIN Hz / Duty A. Clamp: Measure inductive AC current. Opens to 1.25” (31.7mm). B. Conductor Alignment Marks: Used to aid the visual alignment of a conductor when measuring inductive amperage. Greatest accuracy is achieved when the conductor inside the clamp is centered at the intersection of these marks.
  • Page 4 AC/DC Voltage: <750V AC/600V DC True RMS MAX/MIN Hz / Duty • Default = • Press x1 = WARNING • Use CAT III rated Test leads or higher. • Do not attempt to measure more than 750V AC/600V DC. • Keep hands below line when measuring high current levels. •...
  • Page 5: Capacitance (Mfd)

    Diode GOOD DIODE Reverse Bias Displays "OL" • Default = • Press x1 = True RMS • Press x2 = MAX/MIN Hz / Duty • Press x3 = Forward Bias Displays approx. voltage drop BAD DIODE Open Diode Displays "OL" Both directions '0' Both directions (Shorted)
  • Page 6: Non-Contact Voltage

    WARNING • Do not attempt to measure more than 2000µA DC Features: DC Low Amps – Test Lead input Range Resolution Accuracy Overload Protection 600µA 0.1µA ±(1.2% +3 dgts) 2000µA/600V RMS 2000µA 1µA Non-Contact Voltage NCV Sensor located in tip True RMS MAX/MIN Hz / Duty...