Download Print this page
UEi DL469 Instruction Manual

UEi DL469 Instruction Manual

Ac 400a trms clamp meter

Advertisement

Quick Links

AC 400A TRMS Clamp Meter
INSTRUCTION MANUAL
ENGLISH
1000V
CAT III
www.ueitest.com • email: info@ueitest.com
The DL469 is warranted to be free from defects in materials and workmanship
for a period of two years from the date of purchase. If within the warranty
period your instrument should become inoperative from such defects, the unit
will be repaired or replaced at UEi's option. This warranty covers normal use
and does not cover damage which occurs in shipment or failure which results
from alteration, tampering, accident, misuse, abuse, neglect or improper
maintenance. Batteries and consequential damage resulting from failed
batteries are not covered by warranty.
Any implied warranties, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are limited to the express
warranty. UEi shall not be liable for loss of use of the instrument or other
incidental or consequential damages, expenses, or economic loss, or for any
claim or claims for such damage, expenses or economic loss.
A purchase receipt or other proof of original purchase date will be required
before warranty repairs will be rendered. Instruments out of warranty will be
repaired (when repairable) for a service charge
For more information on warranty and service, contact:
www.ueitest.com • Email: info@ueitest.com
This warranty gives you specific legal rights. You may also have other rights,
which vary from state to state.
CAUTION: This symbol indicates that equipment and its accessories
shall be subject to separate collection and correct disposal.
Periodically clean your meter's case using a damp cloth. DO NOT use abrasive,
flammable liquids, cleaning solvents, or strong detergents as they may damage the
finish, impair safety, or affect the reliability of the structural components.
Remove the batteries when instrument is not in use for a prolonged period of time.
Do not expose to high temperatures or humidity. After a period of storage in extreme
conditions exceeding the limits mentioned in the General Specifications section, allow
the instrument to return to normal operating conditions before using it.
Copyright © 2016 UEi. All Rights Reserved.
DL469
True RMS
1-800-547-5740
WARRANTY
1-800-547-5740
DISPOSAL
CLEANING
STORAGE
DL469
CAT Ill
1000V
400A
NCV
µA
A
CAT III 1000V
MAX

Advertisement

loading

Summary of Contents for UEi DL469

  • Page 1 Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss.
  • Page 2: General Specifications

    FEATURES • True RMS • 400A AC • 750V AC / 600V DC • Resistance 40MΩ • DC Microamps 2000µA • Diode test • Non-contact voltage detection • Data hold • Manual ranging option • Worklight • Audible voltage indicator •...
  • Page 3: Category Definitions

    OVERVIEW CAT Ill 1000V 400A S / N : OPEN DL469 µA True RMS CAT III 1000V LOCK A. Clamp: Measure inductive AC current. Opens to 1.25” (31.7mm). B. Conductor Alignment Marks: Used to aid the visual alignment of a conductor when measuring inductive amperage.
  • Page 4: Test Lead Notes

    CAUTION: If the test leads need to be replaced, you must use a new one which should meet EN 61010-031 standard, rated CATIII 1000V or better. AC/DC Voltage: <750V AC/600V DC CAT Ill 1000V 400A DL469 µA True RMS • Default = • Press x1 = CAT III 1000V WARNING •...
  • Page 5 Continuity CAT Ill 1000V 400A DL469 µA True RMS • Press x1 = • Default = CAT III 1000V • Buzzer sounds at less than 40Ω. WARNING • Do not measure resistance on a live circuit. Features: HOLD Open Circuit V...
  • Page 6: Battery Replacement

    DC Low Amps: < 2000µA CAT Ill 1000V 400A DL469 µA True RMS µ CAT III 1000V WARNING • Keep hands below guard when measuring high current levels. • Do not attempt to measure more than 2000µA DC Features: HOLD DC Low Amps –...