Download Print this page

UEi DL220 Instruction Manual

Cativ clamp meter and voltage tester

Advertisement

Quick Links

1.800.561.8187
DL220
CATIV Clamp Meter and
Voltage Tester
INSTRUCTION MANUAL
ENGLISH
600V
CAT IV
WARRANTY
The DL220 is warranted to be free from defects in materials and workmanship
for a period of two years from the date of purchase. If within the warranty
period your instrument should become inoperative from such defects, the unit
will be repaired or replaced at UEi's option. This warranty covers normal use
and does not cover damage which occurs in shipment or failure which results
from alteration, tampering, accident, misuse, abuse, neglect or improper
maintenance. Batteries and consequential damage resulting from failed
batteries are not covered by warranty.
Any implied warranties, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are limited to the express
warranty. UEi shall not be liable for loss of use of the instrument or other
incidental or consequential damages, expenses, or economic loss, or for any
claim or claims for such damage, expenses or economic loss.
A purchase receipt or other proof of original purchase date will be required
before warranty repairs will be rendered. Instruments out of warranty will be
repaired (when repairable) for a service charge.
For more information on warranty and service, contact:
This warranty gives you specific legal rights. You may also have other rights,
which vary from state to state.
DISPOSAL
CAUTION: This symbol indicates that equipment and its accessories
shall be subject to separate collection and correct disposal.
CLEANING
Periodically clean your meter's case using a damp cloth. DO NOT use abrasive,
flammable liquids, cleaning solvents, or strong detergents as they may damage the
finish, impair safety, or affect the reliability of the structural components.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of time.
Do not expose to high temperatures or humidity. After a period of storage in extreme
conditions exceeding the limits mentioned in the General Specifications section, allow
the instrument to return to normal operating conditions before using it.
www.
.com
Copyright © 2016 UEi. All Rights Reserved.
600V
CAT IV
200A
information@itm.com

Advertisement

loading

Summary of Contents for UEi DL220

  • Page 1 Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss.
  • Page 2: General Specifications

    FEATURES • 600V AC/DC • 200A AC • Resistance 2000Ω • Audible continuity • LRA Inrush • Sliding clamp • Auto hold • Auto ranging • Backlight • Low battery indicator • Auto power off • Permanent test leads • Latches for battery compartment •...
  • Page 3: Category Definitions

    SYMBOLS AC (Alternating current) DC (Direct current) Negative DC AC/DC Overload: Range Exceeded Auto-Hold/Capture Value Low Battery Voltage Amperage Ohms/Resistance Continuity High Voltage Indication Warning or Caution Ground Double Insulation Dangerous Levels (Protection to Class II) Safe for disconnect from live conductors CATEGORY DEFINITIONS Measurement...
  • Page 4 Auto On/Auto power off (APO) A-HOLD LRA INRUSH • Default = • Press x1 = • Press x2 = • Press any button to power on meter. • Press and hold AC/DC Volts/Power button to power off meter. • Auto power off (Apo) after 10 minutes of inactivity. (5 minutes in resistance mode) •...
  • Page 5: Lra Inrush

    • The meter must be in AC Amps mode first to be placed into LRA measurement mode. • The UEi LRA Inrush is programmed to properly capture the starting current for compressor motors. • Press and hold A-Hold/LRA Inrush button – INRUSH will now be shown on the display.
  • Page 6: Battery Replacement

    Test Lead Notes CatIV 600V Measurement Locations CATIV 600V CATIV 600V • Ensure the test lead shield is pressed firmly in place. Failure to use the CATIV shield increases arc-flash risk. CATII 1000V Measurement Locations 18mm CATIV CATII 600V 1000V 18mm •...