Download Print this page
UEi DL479 Instruction Manual

UEi DL479 Instruction Manual

Ac 600a trms hvac/r clamp meter
Hide thumbs Also See for DL479:

Advertisement

Quick Links

DL479
AC 600A TRMS HVAC/R
Clamp Meter
INSTRUCTION MANUAL
ENGLISH
True RMS
600V
Hz / Duty
CAT IV
1000V
CAT III
1-800-547-5740
www.ueitest.com • email: info@ueitest.com
CATEGORY DEFINITIONS
Measurement
Short-Curcuit
Location in the
(typical) kA
building installation
Category
a
II
< 10
Circuits connected to mains socket
outlets and similar points in the MAINS
installation
III
< 50
Mains distributions parts of the building
IV
> 50
Source of the mains installation in the
building
WARRANTY
The DL479 is warranted to be free from defects in materials and workmanship
for a period of two years from the date of purchase. If within the warranty
period your instrument should become inoperative from such defects, the unit
will be repaired or replaced at UEi's option. This warranty covers normal use
and does not cover damage which occurs in shipment or failure which results
from alteration, tampering, accident, misuse, abuse, neglect or improper
maintenance. Batteries and consequential damage resulting from failed
batteries are not covered by warranty.
Any implied warranties, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are limited to the express
warranty. UEi shall not be liable for loss of use of the instrument or other
incidental or consequential damages, expenses, or economic loss, or for any
claim or claims for such damage, expenses or economic loss.
A purchase receipt or other proof of original purchase date will be required
before warranty repairs will be rendered. Instruments out of warranty will be
repaired (when repairable) for a service charge.
For more information on warranty and service, contact:
www.ueitest.com • Email: info@ueitest.com
1-800-547-5740
This warranty gives you specific legal rights. You may also have other rights,
which vary from state to state.
DISPOSAL
CAUTION: This symbol indicates that equipment and its accessories
shall be subject to separate collection and correct disposal.
CLEANING
Periodically clean your meter's case using a damp cloth. DO NOT use abrasive,
flammable liquids, cleaning solvents, or strong detergents as they may damage the
finish, impair safety, or affect the reliability of the structural components.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of time.
Do not expose to high temperatures or humidity. After a period of storage in extreme
conditions exceeding the limits mentioned in the General Specifications section, allow
the instrument to return to normal operating conditions before using it.
Copyright © 2016 UEi. All Rights Reserved.
• True RMS
• 600A AC
• 750V AC/600V DC
• Resistance 60MΩ
• Capacitance 2000µF
• Temperature 14˚ to 752˚F (-10˚ to 400˚C)
• DC Microamps 2000µA
• Frequency/Duty Cycle
• Data hold
• Min/Max (25 ms fast capture)
• Manual ranging option
• Operating Temperature:
• Storage Temperature
• Operating Humidity:
• Operating Altitude:
• Pollution Degree:
• Display:
• Backlight:
• Refresh Rate:
• Over-range:
• Dimensions:
• Item Weight:
• Calibration:
• CAT Rating:
• Certifications:
• Battery Type:
• Test Leads:
• Accuracy:
MAX/MIN
WARNING
Read entire Safety Notes section regarding potential hazards and proper
instructions before using this meter. In this manual the word "WARNING" is
used to indicate conditions or actions that may pose physical hazards to the
user. The word "CAUTION" is used to indicate conditions or actions that may
damage this instrument.
WARNING
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
WARNING
• Before each use, verify meter operation by measuring a known voltage
or current.
• Never use the meter on a circuit with voltages that exceed the category
based rating of this meter.
• Do not use this meter during electrical storms or in wet weather.
• Do not use the meter or test leads if they appear damaged.
• Ensure meter leads are fully seated and keep fingers away from the
metal probe contact when making measurements. Always grip the leads
behind the finger guards molded into the probe.
• Do not open the meter to replace batteries while the probes are
connected.
• Use caution when working with voltages above 60V DC or 25V AC RMS.
Such voltages pose shock hazards.
• To avoid false readings that can lead to electrical shock, replace
batteries if a low battery indicator appears.
• Unless measuring voltage or current, shut off and lockout power before
measuring resistance or capacitance.
• Always adhere to national and local safety codes. Use proper personal
protective equipment (PPE) to prevent shock and arc blast injury where
hazardous live conductors are exposed.
• Always turn off power to a circuit or assembly under test before cutting,
unsoldering or breaking the current path. Even small amounts of current
can be dangerous.
• Always disconnect the live test lead before disconnecting the common
test lead from the circuit.
• In the event of electrical shock, ALWAYS bring the victim to the
emergency room for evaluation, regardless of victim's apparent recovery.
Electrical shock can cause unstable heart rhythms that may need
medical attention.
• If any of the following occur during testing, turn off the power source to
the circuit being tested: arching, flame, smoke, extreme heat, smell of
burning materials or discoloration or melting of components.
WARNING
Higher voltages and currents require greater awareness of physical safety
hazards. Before connecting the test leads, turn off power to the circuit under
test, set meter to the desired function and range, connect the test leads to
the meter first, then connect to the circuit under test. Reapply power. If an
erroneous reading is observed, disconnect power immediately and recheck all
settings and connections.
WARNING
This meter is designed for trade professionals who are familiar with the
hazards of their trade. Observe all recommended safety procedures that
include proper lock-out utilization and use of personal protective equipment
that includes safety glasses, gloves and flame resistant clothing.
FEATURES
• Backlight
• Worklight
• Audible voltage indicator
• Low battery indicator
• Auto power off
• Test lead storage
• Overmolded grip
• Auto-calibration
• Magnetic mount
• Battery compartment latches
GENERAL SPECIFICATIONS
32° to 104°F (0° to 40°C)
14° to 122°F (-10° to 50°C)
<75%
6,562 ft. (2000m)
2
3 5/6" Digits 6,000 Count
Yes
3/sec
"OL" is displayed
8.75" X 3.5" X 1.75"
0.65 lb
Recommended Annually
CAT IV 600V / CAT III 1000V
cETLus 3rd Edition, CATIII 1000V, IEC 61010-1, 61010-2-032,
61010-2-033, CSA C22.2, NO. 61010-1, 61010-2-032,
61010-2-033, 6' Drop Protection, RoHS Compliant,
CE Conformity
(AAA) X 2
Test lead w/Alligator Clips
± (% of reading + # of least significant digits)
IMPORTANT SAFETY WARNINGS
SYMBOLS
AC (Alternating current)
DC (Direct current)
Negative DC
AC/DC Voltage
Auto-ranging
Overload: Range Exceeded
Auto power off Active
Low Battery
Minimum measured value
Non-Contact Voltage
displayed
Hold/Capture Value
Duty Cycle
Maximum measured value
Voltage
displayed
Hertz/Frequency
Ohms/Resistance
Capacitance mode in
Amperage
nanofarads or microfarads
Diode
Micro (x10
-6
or 0.000001)
Nano (x10
or 0.000000001)
Degrees Celsius
-9
Degrees Fahrenheit
Continuity
High Voltage Indication
Milli (x10
-3
or 0.001)
Mega (x10
or 1,000,000)
Nano (x10
or 0.000000001)
6
-9
Kilo (x10
3
or 1,000)
Warning or Caution
Micro (x10
or 0.000001)
Dangerous Levels
-6
Safe for disconnect from live
Ground
conductors
Double Insulation (Protection
High Voltage Indication
to Class II)
OVERVIEW
C
A
B
D
E
F
G
S
H
I
J
T
U
K
V
M
True RMS
L
N
W
MAX/MIN
Hz / Duty
O
P
Q
R
A. Clamp: Measure inductive AC current. Opens to 1.25" (31.7mm).
B. Conductor Alignment Marks: Used to aid the visual alignment of a conductor
when measuring inductive amperage. Greatest accuracy is achieved when the
conductor inside the clamp is centered at the intersection of these marks.
C. Wire Separation Tab/NCV sensor: Used to isolate an individual wire from a
bundle for testing. NCV sensor detects live voltage.
D. Test Lead Holder: Used for hand-free use of the test probes.
E. Worklight: Lights clamp area in dark work environments.
F. Category Max Indicator: Maximum CAT Rating for Clamp/jaw.
G. Hand Guide: Used as a point of reference for the operator's safety.
H. NCV Alert Light: Indicates voltage when in NCV mode.
I. Clamp Lever: Opens and closes current clamp jaw. The clamp uses a high-
tension spring to close the jaw. Do not allow fingers or objects to become
pinched in the base as the jaws close.
J. Hold Button
• Press to hold the reading on the display. Press again to return to live reading.
• Press and hold to turn on Worklight and Backlight. Press and hold again to
turn off.
K. Function Dial: Turns on meter and is used to select the function.
L. Select Button
• Used to choose measurement mode from a single dial selection; AC or DC
volts, Resistance, Continuity, Diode or Capacitance, ˚F or ˚C in temperature mode.
• Press and hold the button while turning the meter on to disable Apo
(auto power off).
M. Max/Min Button
• Press to enter MAX/MIN mode.
• Press repeatedly to alternate between Maximum and Minimum readings.
• Press and hold to return to live readings.
N. Range Button:
• Press repeatedly to cycle through manual ranges.
• Press and hold to return to auto ranging mode.
• AT is displayed on LCD only during auto ranging mode.
O. Apo: Auto power off after 30 minutes of use. Press and hold the SELECT button
while turning the meter on to disable Apo (auto power off).
P. Display:
• High contrast display.
Q. Category Max Indicator: Maximum CAT Rating for input jacks.
R. Input Jacks: Multifunction and Common jacks.
• Multifunction input port used for measuring: AC or DC volts, Resistance,
Continuity, Diode, Capacitacne, DC µA and temperature.
• Use CAT III test leads or higher.
S. Serial Number
T. Magnetic Mount: For hands-free work.
U. Battery Cover: Easy access for replacing batteries.
V. Battery Cover Latches: Convenient, quick opening.
W. Test lead holders: For storing test leads when not in use.
4mm
Test Lead Notes
Cat IV and CAT III Measurement Locations
CATIV
600V
4mm
CATIV
600V
• Ensure the test lead shield is pressed firmly in place. Failure to use the CAT
IV shield increases arc-flash risk.
CAT II Measurement Locations
18mm
CATIV
600V
18mm
• CAT IV shields may be removed for CAT II locations. This will allow testing
CATIV
on recessed conductors such as standard wall outlets. Take care not to lose
600V
the shields.
WARNING: Test Lead category protections apply only to test leads and
should not be confused with the meter's specific CAT rating. Observe the
maximum category protection indicated on the meter the test leads are
plugged into.
CAUTION: If the test leads need to be replaced, you must use a new one
which should meet EN 61010-031 standard, rated CATIII 1000V or better.
Battery Replacement
LOCK
S / N :
OPEN
When the batteries are too low for safe
operation, the Low Battery indicator will display.
• Rotate latches until Unlock symbols are aligned
with arrows. Remove battery cover.
• Replace the old batteries with 2 new (AAA)
batteries.
• Replace the battery cover.
• Rotate latches until the lock symbols are aligned
with arrows.
LOCK
S / N :
OPEN
LOCK
CATII
1000V
CATII
1000V
OPEN
17211 • 0616

Advertisement

loading

Summary of Contents for UEi DL479

  • Page 1 This meter is designed for trade professionals who are familiar with the warranty. UEi shall not be liable for loss of use of the instrument or other CATIV CATII hazards of their trade.
  • Page 2 AC/DC Voltage: <750V AC/600V DC Diode WARNING • Do not attempt to measure more than 2000µA DC GOOD DIODE Features: HOLD DC Low Amps – Test Lead input Range Resolution Accuracy Overload Protection Reverse Bias 600µA 0.1µA ±(1.2% +3 dgts) 2000µA/600V RMS Displays "OL"...