UEi DL599 Instruction Manual

UEi DL599 Instruction Manual

Wireless trms clamp meter w/ 3-phase & unbalanced motor tests
Hide thumbs Also See for DL599:

Advertisement

Find Quality Products Online at:
Wireless TRMS Clamp Meter w/
3-Phase & Unbalanced Motor Tests
INSTRUCTION MANUAL
ENGLISH
GlobalTestSupply
www.
DL599
A U T O
INRUSH
RANGE
MIN/MAX
ZERO
°C/°F
PEAK
Hz / Duty
T r u e R M S
C L A M P M E T E R
30V
T
T
1
2
CATIV 600V
CATIII 1000V
TEMP
.com
sales@GlobalTestSupply.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DL599 and is the answer not in the manual?

Questions and answers

Summary of Contents for UEi DL599

  • Page 1 DL599 Wireless TRMS Clamp Meter w/ 3-Phase & Unbalanced Motor Tests INSTRUCTION MANUAL ENGLISH A U T O INRUSH RANGE MIN/MAX ZERO °C/°F PEAK Hz / Duty T r u e R M S C L A M P M E T E R...
  • Page 2: Table Of Contents

    Table Of Contents FUNCTIONS....................3 FEATURES .....................3 GENERAL SPECIFICATIONS .............3 IMPORTANT SAFETY WARNINGS ..........4 SYMBOLS .....................5 CATEGORY DEFINITIONS..............5 OVERVIEW ..................6 - 7 OPERATING INSTRUCTIONS Non-Contact Voltage..............7 Voltage: 1000V AC/DC............. 8 Frequency (Hz) / Duty Cycle ............9 Low Z (Low Impedance) ............10 Low Pass Filter...............
  • Page 3: Functions

    • Test Leads: Test leads w/ alligator clips & back probes Use ATL58 test leads w/ ABP3 back probes and AAC3 alligator clips. ATL55, ATL57 and ATLTX will not work with DL599 GlobalTestSupply www. .com Find Quality Products Online at:...
  • Page 4: Important Safety Warnings

    Important Safety Warnings WARNING Read entire Safety Notes section regarding potential hazards and proper instructions before using this meter. In this manual the word “WARNING” is used to indicate conditions or actions that may pose physical hazards to the user. The word “CAUTION” is used to indicate conditions or actions that may damage this instrument.
  • Page 5: Symbols

    Symbols AC (Alternating current) DC (Direct current) Negative AC/DC Voltage or Current Auto-ranging Overload: Range Exceeded Low pass Filter Wireless Connection Auto power off Active Non-Contact Voltage Low Battery Hold/Capture Value Minimum measured Maximum measured value displayed value displayed Duty Cycle Hertz/Frequency Voltage Inrush...
  • Page 6: Overview

    Overview A U T O INRUSH RANGE MIN/MAX ZERO °C/°F PEAK Hz / Duty T r u e R M S C L A M P M E T E R CATIV 600V CATIII 1000V TEMP A. Clamp: Measure inductive AC/DC current. Opens to 1.25” (32.0mm). B.
  • Page 7: Non-Contact Voltage

    Overview (Cont.) K. Category Max Indicator: Maximum CAT Rating for input jacks. L. Test Lead Input Jacks: Multifunction and Positive input jacks. • Multifunction input port used for measuring: AC or DC volts, resistance, continuity, diode, capacitance, AC or DC µA. M.
  • Page 8: Voltage: 1000V Ac/Dc

    Voltage: 1000V AC/DC High Voltage • Default = Auto Selection Alert • Press SELECT x1 = A U T O • Press SELECT x2 = • Press RANGE to select resolution INRUSH RANGE MIN/MAX ZERO °C/°F PEAK Hz / Duty T r u e R M S C L A M P M E T E R CATIV 600V...
  • Page 9: Frequency (Hz) / Duty Cycle

    Frequency (Hz) / Duty Cycle • Default = Auto Selection • Press SELECT x1 = • Press and hold ZERO x1 = A U T O • Press and hold ZERO x2 = • Press RANGE to select resolution INRUSH RANGE MIN/MAX ZERO...
  • Page 10: Low Z (Low Impedance)

    Low Z (Low Impedance) Low Z • Rotate Selector Dial to Low Z • Default = Auto Selection • Press SELECT x1 = • Press SELECT x2 = Features: A U T O SELECT INRUSH RANGE MIN/MAX ZERO °C/°F PEAK Hz / Duty T r u e R M S C L A M P M E T E R...
  • Page 11: Ac/Dc Amps <600A Jaw

    AC/DC Amps <600A Jaw Single Conductor Only A U T O A U T O • Default = Auto Selection • Press SELECT x1 = INRUSH INRUSH RANGE RANGE MIN/MAX MIN/MAX ZERO ZERO °C/°F °C/°F PEAK PEAK Hz / Duty Hz / Duty •...
  • Page 12: Ac/Dc Microamps: <2000 A

    AC/DC Microamps: <2000µA • Default = Auto Selection • Press SELECT x1 = • Press SELECT x2 = A U T O • Readings show on lower display INRUSH RANGE MIN/MAX ZERO °C/°F PEAK Hz / Duty T r u e R M S C L A M P M E T E R CATIV 600V CATIII 1000V...
  • Page 13: Lra Inrush

    C L A M P M E T E R CATIV 600V CATIII 1000V TEMP The UEi LRA Inrush is programmed to properly capture the starting current for compressor motors. • Select AC Amps. • Select the range capable of capturing the maximum value.
  • Page 14: Voltage Unbalance

    Voltage Unbalance 1. Set the Dial to V range 2. Press and hold RANGE and MIN/MAX button to enter Phase rotation mode. Press RANGE button to enter Voltage Unbalance test mode Upper display indicates “V1V2” Press Min/Max button to enter Testing standby mode. “V1V2”...
  • Page 15: Resistance: < 60M

    Resistance: < 60M • Default = • Press RANGE to select resolution A U T O INRUSH RANGE MIN/MAX ZERO °C/°F PEAK Hz / Duty T r u e R M S C L A M P M E T E R CATIV 600V CATIII 1000V TEMP...
  • Page 16: Temperature Calibration

    Temperature Calibration The new DL599 clamp meter offers a digital field temperature calibration procedure to make the process easier. Here are the steps. 1) Turn on DL599 while holding down RANGE button. 2) When ‘FLD1’ is displayed on LCD, press the ZERO button.
  • Page 17: Capacitance

    Capacitance • Default = • Press SELECT x3 = A U T O • Press RANGE to select resolution INRUSH RANGE MIN/MAX ZERO °C/°F PEAK Hz / Duty T r u e R M S C L A M P M E T E R CATIV 600V CATIII 1000V TEMP...
  • Page 18: App Overview

    App Overview • In the App stores Google Play and the App Store, search “DL599”. • App is compatible with iOS® 12.0 and up and Android™ 6.0 and up. • If searching for the iPad version, you may have to filter for “iPhone” only.
  • Page 19: Test Lead Notes

    CAUTION: If the test leads need to be replaced, you must use a new one which should meet EN 61010-031 standard, rated CATIII 1000V or better. NOTE: DL599 works with UEi ATL58 test leads, ABP3 back probes and AAC3 alligator clips.
  • Page 20: Warranty

    Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss.

This manual is also suitable for:

053533509137Dl589

Table of Contents