OPERATION
Gas-operation mode
The 12V-operation mode is selected by pushing the button 1 (see TD S23). The button has
to be pushed several times, until the LED next to the Symbol of the Gas lights up or the
(AES-) display indicates GAS.
Ignition while operating with gas.
The controlling electronics initiates max. 3 ignition attempts in the following cycle:
25 sec. ignition, if not ok, 2 min. ventilation break
25 sec. ignition, if not ok, 2 min. ventilation break
25 sec. Ignition, if not ok,
FAULT INDICATION
by flashing of the
fault-LED
and the
gas operation LED
(see TD S23).
TD S26