SERVICE + MAINTENANCE
Service Mode AES
The Service Mode is activated by keeping pressed down the temperature button
and switching on the main button.
After this the 7-Segment-Display shows „1". By pushing the temperature button,
the different test-steps can be activated:
1 = activates 120 V heating element (120V must be available)
2 = activates 120V relay (120V has not to be necessarily available)
3 = activates 12 V heating element (D+ and 12V supply has to be available)
4 = Intern test step (is not indicated)
5 = activates burner control device – output (Gas operation)
6 = activates frame heating
7 = activates interior lights (Except for electrical lock)
52