120V-Operation Mode (Manual) - Dometic RM 8 Series Service Manual

Absortion refrigerator for leisure vehicles
Hide thumbs Also See for RM 8 Series:
Table of Contents

Advertisement

OPERATION

120V-operation mode (manual)

The 12V-operation mode is selected by pushing the button 1 (see TD S27). The button has
to be pushed several times, until the 7-segment-display indicates 120.
Detection of undervoltage while operating with 120V
The controlling electronics is equipped with a detection of undervoltage.
Conditions:
- Limit value: 103 V AC (min. 101 V, max. 105 V)
-120V-Relais switches off after ca. 5 seconds "observation"
- Switches back from undervoltage mode to normal mode after ca. 20 seconds
- Undervoltage fault indication by flashing of display 2 + 3 and acoustic signal (see TD S27).
TD S28