Refrigerator operation
4.3.2 Gas operation (Liquid gas)
The refrigerator must be operated using
liquid gas (propane, butane) (no natural gas
or town gas). When using LPG gas, please
consider that the burner needs cleaning at
shorter intervals due to the gas combustion
method (2 - 3 times per year recommended
For physical reasons, gas ignition faults
could occur starting from an altitude above
sea level of approx. 3280 ft. / 1000 m (No
malfunction!)
On the initial refrigerator start-up or after a
cylinder change, air may be trapped in the
gas line. To purge the air from the lines,
switch on the refrigerator and any other gas
appliances (e.g. stove) for a short time. The
gas ignites without delay.
WARNING!
As a basic rule, gas operation is prohibi-
ted in petrol stations
Prior to starting the refrigerator in gas
mode :
Open the gas cylinder valve.
Open the shut-off valve for gas supply to the
refrigerator.
MES Appliances
1
Mode
1. Press button "1" several times until the indica-
tor LED (F)
illuminates.
2. The ignition process is activated automatical-
ly by means of an automatic igniter.
The ignition system will make 2 ignition attempts
with 25 seconds interval when the burner fails to
light. If repeated attempts fail to start the opera-
tion, a fault is indicated ( please refer to failure
indication ).
16
F
Fig. 12
Fig. 13