EN
A, A EX 2GD, A EX 3GD - Vacuum Cleaners
NOTE! If the vacuum cleaner comes with a control system for timer controlled cleaning,
see it's settings instructions for information regarding its use.
6.3
Replace the cartridge filter
NOTE!
•
If the filter is placed into a dust bag for disposal, tie off the dust bag, see figure 9.
•
When using a cartridge filter and filter bag, see figure 14.
Table 6-1: Filter house parts, see figure 4(A)
Filterhouse NCF parts
1. Bolt
1.
Turn off vacuum cleaner.
2.
Remove the filter and place it into a container or dust bag.
3.
Put in the new filter.
6.4
Replace filter candles (A & A EX 3GD)
NOTE! 5 Nm/(0,5 kpm)/(3,5 lbft) maximum to tighten the bolt, see figure 4(B).
6.5
Replace the filter bag
NOTE! If the filter bag is placed into a dust bag for disposal, tie off the dust bag, see
figure 9.
1.
Turn off vacuum cleaner.
2.
Empty pre-separator, if one is used.
3.
Remove filter basket and filter bag.
4.
Replace filter bag.
6.6
Replace the filter package
NOTE!
•
If the filter package is placed into a dust bag for disposal, tie off the dust bag, see
figure 9.
See figure 13. The particles collect on the outside of the filter. Cleaning is carried out every
other hour or when the vacuum performance decreases. Replacing the entire filter package
is recommended. When only changing the socks, the filter ring should also be replaced.
6.7
Replace dust bags
WARNING!
•
Always use
•
Connect the upper and lower ground wires to the bag.
30
2. O-ring
Risk of personal injury (A EX 2GD & 3GD).
approved bulk bags.
3. Candle