Test Sequence - Nespresso Citiz Service Manual

Hide thumbs Also See for Citiz:
Table of Contents

Advertisement

This test sequence is 
not applicable for cof­ 
fee machines with 
two­wire power cords (with­ 
out ground pin). 
Symbolic illustration 
of test equipment. 
The coffee machine 
Citiz & Co has 2 test 
holes to check both 
thermoblocks. 
142 
F U N C T I O N   T E S T S 
9.8.3  Test sequence 
Danger of electrocution! 
Do not plug in the coffee machine during the protective earth continuity 
test. 
Read and observe safety instructions in user manual of test equipment. 
1)  Connect black measuring cable to 
ground pin of power plug with an alli­ 
gator clip (example shown: Swiss 
power plug). 
2)  Switch on test equipment and select 
protective earth continuity test. 
Test holes on bottom of Citiz / Citiz & milk / Citiz & Co  platforms 
3)  Insert tip of red test probe in test hole 
and touch thermoblock. 
4)  Press "measure" button and read off 
displayed resistance. 
The resistance must be lower than 
0.3 Ohm. 
5)  Fill in measured value(s) in a test 
report.
Citiz service manual 

Advertisement

Table of Contents
loading

Table of Contents