If present, disconnect ground wire (15, part of thermoblock assembly). 
• 
If the thermoblock or core unit has to be replaced, disconnect milk frother connector 
(57). Otherwise the core unit can be removed together with this connector (see page 
73). 
• 
Remove water tank connector (53, see page 71). 
Assembly checkpoints 
• 
All covers are assembled on the core unit. 
• 
Check that wiring between core unit and platform is led through cable fixation (71). 
• 
Use marked cable guides to lay wires. 
• 
Check wiring of milk frother connector (57), see detail. 
• 
Check wiring of mains switch (54), see "Wiring diagrams ­ model Citiz & milk, 
EF 485/486" on page 124 and following. 
• 
During assembly of the water tank connector (53) on the platform, each of its 3 
latches has to engage with an audible click. 
R E P A I R S 
Citiz service manual 
The flat receptacle on 
the ground wire has a 
special connector 
latching (see detail). Press 
down lever at first, then pull 
off receptacle.
79 