4)  Remove milk frother from platform. 
5)  Insert red test probe in central opening 
of milk frother connector (ground con­ 
nection). 
6)  Press "measure" button. 
7)  Read off displayed insulation resist­ 
ance or test result. 
8)  Switch off test equipment. 
9)  Short red with black test probe to 
make sure that test voltage is dis­ 
charged. 
10) Fill in result in test report. 
9.9.4  What to do if the insulation test fails 
Risk of damage! 
A sparkover can damage the electronic control board and sensors etc.
• 
Assume that the coffee machine is defect after a failed insulation test. 
• 
Check wiring and locate fault. After fault clearance proceed with troubleshooting 
check list (see page 49). 
• 
In case of doubt an insultation test on the milk frother alone can be carried out on 
the coffee machine Citiz & milk: touch phase and neutral contacts at the bottom with 
one test probe successively and the metallic upper part with the other test probe. 
If insulation test fails, replace milk frother. 