5� Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• Select an appropriate mounting location, taking
the reach and motion detection into considera-
tion. (Fig� 4�1)
• Aiming the sensor-switched floodlight. (Fig� 4�4)
The most reliable motion detection is achieved
by mounting the unit to face across the direction
in which people walk and by making sure no
obstacles (e.g. trees, walls etc.) interrupt the line of
sensor vision. (Fig� 4�2 / 4�3)
Mounting procedure
• Switch OFF power supply. (Fig� 3�7)
• Undo retaining screw. (Fig� 4�5)
• Detach enclosure (B) from wall mount (C).
(Fig� 4�6)
• Detach plug-in terminal (male) from wall mount.
(Fig� 4�7)
• Mark drill holes. (Fig� 4�8)
• Drill holes and fit wall plugs. (Fig� 4�9)
• Fit sealing plug. (Fig� 4�10)
– Power supply lead, concealed (Fig� 4�11)
– Power supply lead, surface-mounted,
with spacers (Fig� 4�12)
• Connect conductors. (Fig� 4�13)
• Connect plug-in terminal. (Fig� 4�14)
• Fit enclosure onto wall mount. (Fig� 4�15)
• Screw in retaining screw. (Fig� 4�16)
• Switch ON power supply. (Fig� 4�16)
• Make settings
"6� Function"
6� Function
The sensor-switched LED floodlight will also work
without being integrated into a Z-Wave network.
In this case, the time setting is permanently set
to 3 minutes. When putting the floodlight into
operation, it will switch OFF after the 10-second
calibration phase and is then activated for sensor
mode. The floodlight can now be integrated into
the Z-Wave network.
The settings can be made via control dials or via
Z-Wave network. The settings last selected will
always be in effect regardless of whether they were
made via the control dials or via Z-Wave network.
Factory settings
Twilight level
: 2000 lux
Time setting: 3 min
Twilight setting (Fig� 5�1/E)
infinitely variable
Control dial set to
= twilight operation approx.
2 lux
Control dial set to
= daylight operation approx.
2000 lux
Note: To adjust the detection zone in daylight, the
control dial must be set to
= daylight operation.
Reach setting/adjustment
The detection zone can be optimised to suit
requirements.
Sensor unit
– Sensor unit swivels through 180°. (Fig� 5�3)
– Sensor unit tilts through 90°. (Fig� 5�6)
Adhesive shrouds (Fig� 5�4)
The film shroud can be used for masking out any
number of lens segments to limit reach as required.
Inadvertent triggering is ruled out or the sensor can
be targeted to watch over danger spots (Fig� 5�5).
Other: Floodlight adjustment range
(Fig�3�2 / 3�3 / 5�2)
7� Integration into Z-Wave networks
This product can be operated in any Z-Wave net-
work with other Z-Wave certified devices from oth-
er manufacturers. All non-battery operated nodes
within the network will act as repeaters regardless
of vendor to increase reliability of the network.
Inclusion
Add
Exclusion
Remove
These instructions for including and excluding
STEINEL Z-Wave products have been written for
the Smart Friends system. They may not always
apply to other Z-Wave products. You will find
further details in the description of your Z-Wave
controller. (To start the floodlight's inclusion or
exclusion mode, turn the device's control dial
"Set" and back to "0" within 5 seconds).
Following exclusion, all configuration parameters
(time, sensitivity etc.) remain intact until next inclu-
sion and the light now works in standalone mode –
as a result, Z-Wave can also be used for the light's
standalone setting.
– 14 –
Z-Wave control dial
Control dial for inclusion and
exclusion as well as for returning
the device to the factory setting.
Adding XLED home 2 to the Smart Friends
system:
1
Download the Smart Friends app from the
app store.
2
In the rooms view, activate the edit mode.
3
Select the chosen room and press the "Add
device" button.
4
To put the device into inclusion mode, turn the
device's control dial
"0" within 5 seconds. The status LED
up to show that this mode is selected.
5
The app displays a confirmation message once
inclusion has been successfully completed.
Removing XLED home 2 from the Smart Friends
system:
1
In the rooms view, activate the edit mode.
Select the device in the chosen room and
2
press the "delete"
button. Press delete and
follow the instructions in the app.
3
To put the device into exclusion mode, turn the
device's control dial
"0" within 5 seconds. The red status LED
lights up to show that this mode is selected.
4
The app displays a confirmation message once
exclusion has been successfully completed.
Setting XLED home 2 with the app
to
– After programming, an ON/OFF scene is auto-
matically created in the app.
– The following setting values are then automati-
cally stored:
a) Twilight setting = control-dial setting
b) Time setting = 3 min switch-OFF delay
– The twilight and time settings can be selected to
the accuracy of one lux and one second respec-
tively in the "Scene" menu.
Resetting XLED home 2 to the factory
settings:
Please only perform these steps if the main net-
work controller is missing or not working for other
reasons.
1
Turn the device's control dial
move it to "Reset" within 5 seconds.
2
The status LED
the light has been reset.
3
The device is now no longer included in the
Z-Wave system and has been returned to
factory settings.
Note: the current firmware version for the light is
available for downloading from z-wave�steinel�de.
8� Operation/maintenance
The unit is not suitable for burglar alarm systems as
it is not tamperproof in the manner prescribed for
such systems. Weather can affect the operation of
the sensor-switched LED floodlight. Strong gusts
of wind, snow, rain and hail may cause the light
to come ON when it is not wanted because the
sensor is unable to distinguish between sudden
to "Set" and back to
changes in temperature and sources of heat.
lights
The detector lens may be cleaned with a damp
cloth if it gets dirty (do not use cleaning agents).
9� EC Declaration of Conformity
STEINEL Vertrieb GmbH hereby declares that
the XLED home 2 Z-Wave radio equipment type
conforms to Directive 2014/53/EU. The full wording
of the EU Declaration of Conformity is available for
downloading from the following Internet address:
http://www�steinel�de
to "Set" and back to
10� Warranty
This STEINEL product has been manufactured with
utmost care, tested for proper operation and safety
and then subjected to random sample inspection.
Steinel guarantees that it is in perfect condition
and proper working order. The warranty period is
5 years and starts on the date of sale to the con-
sumer. We will remedy defects caused by material
flaws or manufacturing faults. The warranty will be
met by repair or replacement of defective parts at
our own discretion.
– 15 –
to "Set" and
briefly flashes to show that

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xled home 2 xlXled home 2 z-wave

Table of Contents