  • Page 1 User Manual DZ81-MA3UI5C Intelligence Power Meter User Manual (V1.0) Heyuan Intelligence Technology Co.,Ltd.
  • Page 2 User Manual IMPORTANT DECLARATIONS Copyright © 2018 Heyuan Intelligence Technology Co., Ltd All Rights Reserved 1. This manual may not be reproduced, copied, transmitted or transcribed in whole or in part by any means without the expressed written permission of Heyuan.
  • Page 3: Table Of Contents

    User Manual Contents Chapter 1 Meter Overview………………………………………………………….1 1.1 Overview …………………………………………………….....1 1.2 Main Functions………………………………………………………..1 Chapter 2 Specifications……………………………………………………………2 2.1 Dimension …………………………………………………....2 2.2 Installation………………………………………………………………2 2.3 Technical Parameters………………………………………………..2 2.4 Wiring …………………………………………………………………..3 Chapter 3 Meter Display and Operation…………………………………………..6 3.1 Parameters Display ………………………………………....6 3.2 Parameters Setting Operation………………………………………..9 Chapter 4 After-sales Service …………………………………………………….14 Chapter 5 Contact Us ……………………………………………………..……...14...
  • Page 4: Chapter 1 Meter Overview

    Chapter 1 Meter Overview 1.1 Overview DZ81-MA3UI5C is an advanced, smart networked multifunctional energy meter. It is widely used in power distribution sites, energy management systems and intelligent monitoring systems of different industries. Measuring all parameters: three phase voltage, current, line voltage, zero-sequence current,...
  • Page 5: Wiring

    User Manual Voltage/Current: 0.2% Energy Accuracy: Class 0.5 Power Factor: 0.1% 2.3.4 Working Condition Operating Temperature: -25℃~+70℃ Storage Temperature: -40℃~+85℃ Relative Humidity: 20%~90%(non-condensing) 2.3.5 Communication RS485/Modbus-RTU Communication Protocol Baud Rate: 2400~19200bps (programmable) Technical Parameters-MA3UI5C Voltage:0.2, Current:0.2, Frequency:0.05Hz, Power factor:0.5 Accuracy Class Active power:0.5, Reactive power:0.5, Appearent power:0.5 Active energy: 0.5, Reactive energy: 2 Rated Value...
  • Page 6 User Manual The 3-Phase 4-Line wiring mode is commonly used in low voltage electric distribution power systems. The UL(voltage wiring mode) parameter should be set as 0, the IL(current wiring mode) parameter should be set as 0 at the parameter setting interface. B Three-Phase Three-Line open Delta Mode (2LL, 2CT) Open delta wiring mode is often used in high voltage systems.
  • Page 7 User Manual A Power Supply The power supply for this meter is AC 85-265V (45-55Hz) or DC 85-300V. Terminals for the power supply are (L/+,N/-). The typical power supply wiring is as followed: If the quality of power is poor or there is an EMI problem, it’s recommended to equip an EMC filter in the auxiliary power supply loop.
  • Page 8: Chapter 3 Meter Display And Operation

    User Manual The terminal PE1-/PE1+ are used for active energy pulse output. The terminal PE2-/PE2+ are used for reactive energy pulse output. DI (Digital Input) It is used for measuring real state (connected, disconnected) of external switch, and make a resolution of the 2ms SOE event record.
  • Page 9 User Manual 3) Press button “P”, it will display the values of power parameters circularly.
  • Page 10 User Manual 4) Press button “H”, it will display the total harmonic distortion(THD) of voltage or current circularly. Press “H” or“E” , the meter will display the 2nd~31th HC(harmonic content). The harmonic order will increase from 2nd to 31st by one each time P is pressed. And the harmonic order will decrease by one each time E is pressed.
  • Page 11: Parameters Setting Operation

    User Manual Item Meaning Description Ep: Active Energy; Active; Reactive Eq: Reactive Energy; The number 00~11 represent the current month to the last 11th month. Historical Period Time Number 1~4 represent the 1st to the 4th Reactive Energy in Quadrants quadrant Period :Sharp...
  • Page 12 User Manual flashing. The button “P” is used to plus 1, i.e., the flashing digit will be plus 1 when pressing "P" each time. If the flashing digit is 9, then press "P" and the digit will become 0. The button "E" is used to minus 1, i.e., the flashing digit will minus 1 when pressing "E" each time. If the flashing digit is 0, then press "E"...
  • Page 13 User Manual 5) Voltage Connection Method Setting There are 3 kinds of voltage connection methods optional as follows (by pressing button P or E to choose): 3Ln (Three-phase four-wire 3PT connection) 2Ln (Three-phase four-wire 2PT star (Y) connection) 2LL (Three-Phase Three-Line open delta (Δ) connection) After the setting, please press "V/A"...
  • Page 14: Chapter 4 After-Sales Service

    User Manual Chapter 4 After-sales Service Product Warranty 1.The product warranty period is one year. 2.The company is responsible for free maintenance or exchange within three-year warranty period. 3.The cost of the components and freight shall be charged for improper meter installation and/or operation.