Loosen the screws of the
Medium
medium frame wiring cover
frame wiring
with screwdriver,remove the
cover
electric box cover.
Loosen the clasps of the
medium
medium frame , remove the
frame
medium frame.
1) Take all the connector of
PCB upper side out.(Including
Power cord)
Electrical
2) Detach the outdoor unit
Parts
connection
(Main PCB)
terminal block.
3) If pulling the main PCB up,
it will be taken out.
Remove axial sleeve of louver
air vent,
link, bend the air vent outwards
louver link
and then remove the air vent
and louver link.
1) Loosen fixing earth screws
of right side.
2) Detach the connection pipe.
3) Detach the holder pipe at the
Heat
rear side.
Exchanger
4) Loosen fixing screws of
right and left side.
5) Detach the heat exchanger
from the indoor unit.
wire
from
the
81