Mounting
Remove the Mounting plate.
plate
1) Loosen fixing earth screws
of right side.
2) Detach the connection pipe.
3) Detach the holder pipe at the
Heat
rear side.
Exchanger
4) Loosen fixing screws of
right and left side.
5) Detach the heat exchanger
from the indoor unit.
Remove the screw of the motor
Motor press
press plate and then remove the
plate
press plate.
1) Loosen fixing screws and
detach the motor holder.
2) Loosen fixing screw of fan
Fan Motor
motor. (with a M6 wrench)
&
3) Detach the fan motor from
Cross Fan
the fan.
4) Detach the fan from the left
holder bearing.
Remove screws on volute and
volute
remove the volute.