4195KA, KB, KC, and KS Controllers
BOURDON TUBES
0 to 1.6
0 to 2.5
0 to 4
0 to 6
0 to 10
0 to 16
Metric units
0 to 25
0 to 40
0 to 60
0 to 100
0 to 160
0 to 300
Psig
0 to 30
0 to 60
0 to 100
0 to 200
0 to 300
U.S. units
0 to 600
0 to 1000
0 to 1500
0 to 3000
0 to 5000
1. Minimum or maximum span, or any span in between, may be positioned anywhere within the operating range. For example, if a 0 to 2 bar (0 to 30 psig) sensing element is used
and the minimum span of 1 bar (15 psig) is set, the process indication can be calibrated to a range of −1 to 0 bar (−30 inch Hg to 0 psig), 0 to 1 bar (0 to 15 psig), 1 to 2 bar (15 to 30
psig), 2 to 3 bar (27 to 42 psig) or any value between the operating range minimum and maximum values.
2. Travel stops should be used when the maximum or minimum process pressure will be 5% over or under the calibrated range. For example, a 0 to 2 bar (0 to 30 psig) sensing
element is calibrated for 0.7 to 2 bar (10 to 30 psig), the desired range. The minimum expected pressure is 0 psig and the maximum expected pressure is 2.8 bar (40 psig). Travel
stops must be used to prevent excessive overtravel and undertravel since the maximum allowable overpressure and underpressure is higher than 5% of the 1.4 bar (20 psig) span
which is ±70 mbar (±1 psig).
3. Bourdon tube without travel stops may be pressured to this value without permanent zero shift.
4. Bourdon tube with travel stops set may be pressured to this value without permanent zero shift.
Table 1-5. Optional Process Connections
INPUT RANGE
Bar
Psig
Up to
Up to
0 to 400
0 to 5000
0 to 400 to
0 to 5000 to
0 to 600
0 to 10,000
0 to 400 to
0 to 5000 to
0 to 600
0 to 10,000
1-8
Table 1-4. Process Sensor (Bourdon Tube) Pressure Ratings and Materials
(1)
SPAN
Minimum
Maximum
1
2
2
3.5
7
14
10
20
20
40
20
40
55
70
76
100
160
200
250
350
Psig
Psig
15
30
30
60
50
100
100
200
150
300
300
600
750
1000
1100
1500
2200
3000
3700
5000
CONNECTION
Size
Material
J
Steel or
J
1/2 NPT external
J
or
1/2 NPT
J
stainless
internal
steel
1/2 NPT internal
Stainless steel
1/2 NPT external
Stainless steel
OPERATING RANGE
Minimum
Maximum
Bar
2
−1
4
−1
4
−1
7
−1
−1
−1
0
0
0
0
0
0
Inch Hg
Psig
−30
−30
−30
−30
−30
0
0
0
0
0
OUTPUT SIGNAL
RANGE
Bar
Psig
1. If this pressure is exceeded, control may be impaired.
2. If this pressure is exceeded, damage to the controller may result.
Instruction Manual
(2)
OPERATING
(4)
(3)
LIMITS
3
3.3
6
6.6
6
6.6
10
11
20
22
30
33
60
66
60
66
90
103
135
155
270
310
420
482
Psig
42
48
84
96
140
160
280
320
420
480
840
960
1300
1500
1950
2250
3900
4500
6000
7000
Table 1-6. Supply Pressure Data
NORMAL
OPERATING
SUPPLY
(1)
PRESSURE
0.2 to 1.0
1.4
0.4 to 2.0
2.4
3 to 15
20
6 to 30
35
Form 5207
April 2007
STANDARD
MATERIAL
S31600 (316 SST)
STANDARD
MATERIAL
S31600 (316 SST)
MAXIMUM
(2)
PRESSURE LIMIT
2.8
2.8
40
40