Emerson Fisher KC Series Instruction Manual page 7

Gauge pressure controllers
Table of Contents

Advertisement

Instruction Manual
Form 5207
April 2007
CAPSULE
MATERIAL
Positive pressure
Metric units
N09902
Positive pressure
U.S. units
1. Minimum or maximum span, or any span in between, may be positioned anywhere within the operating range. For example, if a 0 to 350 mbar (0 to 5 psig) sensing element is used
and the minimum span of 1.75 mbar (2.5 psig) is set, the process indication can be calibrated to a range of −340 mbar to −203 mbar (−10 inch Hg to −6 inch Hg), 0 to 172 mbar
(0 to 2.5 psig), 172 to 345 mbar (2.5 to 5 psig), 305 to 480 mbar (4.5 to 7 psig), or any value between minimum and maximum values of operating range.
2. Capsules with the travel stops set may be pressured to this value without permanent zero shift.
4195KA, KB, KC, and KS Controllers
Table 1-3. Process Sensor (Capsular Element) Pressure Ratings
CAPSULAR
STANDARD RANGES
0 to 150 mbar
0 to 400 mbar
0 to 0.6 bar
0.2 to 1 bar
0 to 1 bar
0 to 1.4 bar
0 to 1.6 bar
0.4 to 2 bar
0 to 2 bar
−150 to 0 mbar
−340 to 0 mbar
Vacuum
−400 to 0 mbar
−0.6 to 0 bar
−1 to 0 bar
−50 to 100 mbar
−175 to 175 mbar
−150 to 250 mbar
−0.2 to 0.4 bar
Compound
−0.4 to 0.6 bar
−0.6 to 0.8 bar
−1 to 0.6 bar
−1 to 1 bar
0 to 60 inch wc
0 to 5 psig
0 to 10 psig
3 to 15 psig
0 to 15 psig
0 to 20 psig
6 to 30 psig
0 to 30 psig
−5 to 0 inch Hg
−10 to 0 inch Hg
Vacuum
−20 to 0 inch Hg
−30 to 0 inch Hg
−30 to 30 inch wc
−5 inch Hg to 2.5 psig
−10 inch Hg to 5 psig
Compound
−15 inch Hg to 7.5 psig
−20 inch Hg to 10 psig
−30 inch Hg to 15 psig
(1)
SPAN
Min
Max
100 mbar
160 mbar
−350 mbar
350 mbar
700 mbar
−1 bar
0.35 bar
0.7 bar
−1 bar
0.4 bar
0.8 bar
−1 bar
0.5 bar
1 bar
−1 bar
0.7 bar
1.4 bar
−1 bar
1 bar
2 bar
−1 bar
0.8 bar
1.6 bar
−1 bar
1 bar
2 bar
−1 bar
85 mbar
170 mbar
−350 mbar
170 mbar
340 mbar
−480 mbar
350 mbar
700 mbar
−1 bar
0.35 bar
0.7 bar
−1 bar
0.5 bar
1 bar
−1 bar
100 mbar
160 mbar
−350 mbar
175 mbar
350 mbar
−480 mbar
350 mbar
700 mbar
−1 bar
0.35 bar
0.7 bar
−1 bar
0.5 bar
1 bar
−1 bar
0.7 bar
1.4 bar
−1 bar
1 bar
2 bar
−1 bar
1 bar
2 bar
−1 bar
40 inch wc
60 inch wc
−10 inch Hg
2.5 psig
5 psig
−14 inch Hg
5 psig
10 psig
−30 inch Hg
6 psig
12 psig
−30 inch Hg
7.5 psig
15 psig
−30 inch Hg
10 psig
20 psig
−30 inch Hg
12 psig
24 psig
−30 inch Hg
15 psig
30 psig
−30 inch Hg
2.5 inch Hg
5 inch Hg
−10 inch Hg
5 inch Hg
10 inch Hg
−14 inch Hg
10 inch Hg
20 inch Hg
−30 inch Hg
15 inch Hg
30 inch Hg
−30 inch Hg
40 inch wc
60 inch wc
−10 inch Hg
2.5 psig
5 psig
−14 inch Hg
5 psig
10 psig
−30 inch Hg
7.5 psig
15 psig
−30 inch Hg
10 psig
20 psig
−30 inch Hg
15 psig
30 psig
−30 inch Hg
OPERATING RANGE
OPERATING
LIMIT
Min
Max
350 mbar
510 mbar
1 bar
1.5 bar
1 bar
1.5 bar
1.4 bar
2 bar
1.4 bar
2 bar
1.7 bar
2.5 bar
2.4 bar
3.5 bar
2 bar
3 bar
2.4 bar
3.5 bar
350 mbar
510 mbar
480 mbar
724 mbar
1 bar
1.5 bar
1 bar
1.5 bar
1.4 bar
2 bar
350 mbar
510 mbar
480 mbar
724 mbar
1 bar
1.5 bar
1 bar
1.5 bar
1.4 bar
2 bar
1.7 bar
2.5 bar
2.4 bar
3.5 bar
2.4 bar
3.5 bar
5 psig
7.5 psig
7 psig
10.5 psig
15 psig
22.5 psig
20 psig
30 psig
20 psig
30 psig
25 psig
37.5 psig
30 psig
45 psig
35 psig
52.5 psig
5 psig
7.5 psig
7 psig
10.5 psig
15 psig
22.5 psig
20 psig
30 psig
5 psig
7.5 psig
7 psig
10.5 psig
15 psig
22.5 psig
20 psig
30 psig
25 psig
37.5 psig
35 psig
52.5 psig
(2)
1-7