Factory set-up for Commun Parameters
Param Designation
Language
Motor Speed Unit
Regional Settings
Active set-up
Edit set-up
Display Line 1.1 Small
Display Line 1.2 Small
Display Line 1.3 Small
Display Line 2 Large
Display Line 3 Large
Configuration mode
Control mode
Torque caracteristics
Mode Selection
Motor Construction
Frequency (Hz)
Automatic Motor Adaptation
Motor poles
Slip compens
Starting function
Flying Start
Starting frequency
Starting current
High Starting Torque Max Speed
[rpm]
Stop function
Motor Thermal protection
Motor External Fan
Thermistor ressource
Motor Speed Direction
Reference Range
Reference/Feedback Unit
Preset reference
Reference site
Reference ressource 1
Reference ressource 2
Reference ressource 3
Relative scalling reference ressource
Ramp up time running (sec)
Terminal 18 - Digital input
Terminal 19 - Digital input
Terminal 27 - Digital input
Terminal 29 - Digital input
Terminal 32 - Digital input
Terminal 33 - Digital input
Terminal 53 Low Voltage
Terminal 53 High Voltage
Terminal 53 Low Current (mA)
Terminal 53 High Current (mA)
Terminal 54 Low Voltage
Terminal 54 High Voltage
Terminal 54 Low Current (mA)
Terminal 54 High Current (mA)
Terminal 54 Low ref/Feedb.value
Terminal 54 High ref/Feedb.value
24 | AN000086420674en-000201
Param
Customer
Common parameters
number
access
for all compressors
0-01
r/w
English
0-02
r/w
RPM
0-03
r/w
International
0-10
Read
set-up 1
0-11
r/w
active setup
0-20
r/w
Frequency
0-21
r/w
Motor Current
0-22
r/w
AI53
0-23
r/w
Speed [RPM]
0-24
r/w
Reference %
1-00
r/w
Speed Open Loop
1-01
Read
Flux Sensorless
1-03
Read
Constant Torque
1-05
Read
As Conf. Mode P1-00
1-10
Read
Asynchron
1-23
Read
90 Hz
1-29
Read
Off
1-39
Read
2
1-62
Read
0%
1-72
Read
Vcc+/Flux clockwise
1-73
Read
Disabled
1-75
Read
As Par.1-74 in Hz
1-76
Read
0,00 A
1-77
Read
as P4-11
1-80
Read
Coast
1-90
r/w
No
1-91
r/w
No
1-93
r/w
No
4-10
Read
Clockwise
3-00
r/w
Min - Max
3-01
r/w
rpm
3-10
r/w
0
3-13
r/w
Linked Hand/Auto
3-15
r/w
Input 53
3-16
r/w
No Function
3-17
r/w
No Function
3-18
r/w
No Function
3-41
r/w
9
5-10
r/w
Start
5-11
r/w
No Operation
5-12
r/w
Coast inverse
5-13
r/w
No Operation
5-14
r/w
No Operation
5-15
r/w
No Operation
6-10
r/w
0
6-11
r/w
10
6-12
r/w
4
6-13
r/w
20
6-20
r/w
1
6-21
r/w
5
6-22
r/w
4
6-23
r/w
20
6-24
r/w
-1
6-25
r/w
12
Param Designation
Speed PID Feedback Source
PID Gain
PID Integration time (ms)
PID Diff. time
Process CL Feedback Input resource
Process PID control
Process PID Anti Windup
Process PID start speed
Process PID Gain
Process PID Integration time (ms)
Process PID Diff. time
Switching Frequency
Overmodulation
Function at Mains Imbalance
Reset Mode
Automatic Restart Time (s)
Operation Mode
Trip Delay at Torque Limit
Trip Delay at Inverter Fault
Fan Control
SL Controller Mode
Start Event
Stop Event
Comparator Operand
Comparator Operand
Comparator Operator
Comparator Operator
Comparator Value
Comparator Value
SL Controller Timer
SL Controller Timer
Logic Rule Boolean 1
Logic Rule Boolean 1
Logic Rule Operator 1
Logic Rule Operator 1
Logic Rule Boolean 2
Logic Rule Boolean 2
Logic Rule Operator 2
Logic Rule Operator 2
Logic Rule Boolean 3
Logic Rule Boolean 3
SL Controller Event
SL Controller Event
SL Controller Event
SL Controller Event
SL Controller Event
SL Controller Event
SL Controller Event
SL Controller Action
SL Controller Action
SL Controller Action
SL Controller Action
SL Controller Action
SL Controller Action
SL Controller Action
Param
Customer
Common parameters
number
access
for all compressors
7-00
Read
Motor Feedb. P1-02
7-02
Read
0,005
7-03
Read
200
7-05
Read
Off
7-20
r/w
Analog Input 54
7-30
r/w
Inverse
7-31
r/w
ON
7-32
r/w
3000
7-33
r/w
2
7-34
r/w
9
7-35
r/w
Off
14-01
r/w
4kHz
14-03
r/w
On
14-12
r/w
Warning
14-20
r/w
Auto. reset x 10
14-21
r/w
30
14-22
r/w
Normal operation
14-25
Read
Off
14-26
Read
2
14-52
r/w
Auto
1300
r/w
Off
1301
r/w
Start command
1302
r/w
FALSE
1310.0
r/w
Feedback [unit]
1310.1
r/w
Feedback [unit]
1311.0
r/w
>
1311.1
r/w
<
1312.0
r/w
3.000
1312.1
r/w
1.000
1320.0
r/w
00:05:00.000
1320.1
r/w
00:00:00.000
1340.0
r/w
Digital input DI18
1340.1
r/w
Comparator 1
1341.0
r/w
AND
1341.1
r/w
OR NOT
1342.0
r/w
Comparator 0
1342.1
r/w
Digital input DI18
1343.0
r/w
AND
1343.1
r/w
DISABLED
1344.0
r/w
Start command
1344.1
r/w
FALSE
1351.0
r/w
VRAI
1351.1
r/w
Logic rule 0
1351.2
r/w
TRUE
1351.3
r/w
TRUE
1351.4
r/w
SL Time-out 1
1351.5
r/w
Logic rule 1
1351.6
r/w
SL Time-out 0
1352.0
r/w
Stop
1352.1
r/w
Start timer 0
1352.2
r/w
Start timer 1
1352.3
r/w
Run
1352.4
r/w
No action
1352.5
r/w
Stop
1352.6
r/w
No action