Generator Output; Accessory Ratings; Safety Precautions; Operation - JLG 800a Operation And Safety Manual

Table of Contents

Advertisement

All power regulation components are located in a watertight box
connected by cable to the generator. The generator supplies
power when running at the specified speed with the power
switch on (switch is located on platform). A three-pole, 30 Amp
circuit breaker protects the generator from overload.

Generator Output

ANSI Specifications:
• 3-phase: 240 V, 60 Hz, 7.5 kW
• 1-phase: 240 V/120 V, 60 Hz, 6 kW
CE Specifications:
• 3-phase: 240 V, 7.5 kW, 18.3 A, 1.0-pf
• 1-phase: 240 V, 6.0 kW, 26 A, 1.0-pf
• 1-phase: 120 V, 6.0 kW, 50 A, 1.0-pf
Peak:
• 3-phase: 8.5 kW
• 1-phase: 6.0 kW

Accessory Ratings

• 3000 rpm (50 Hz)
• 3600 rpm (60 Hz)
3121627

Safety Precautions

DO NOT OVERLOAD PLATFORM.
• Ensure no personnel are beneath platform.
• This factory-installed option is available only on specified
models.
• Keep lanyard attached at all times.
• Do not use electrical tools in water.
• Use correct voltage for tool being used.
• Do not overload circuit.
Preparation and Inspection
• Ensure generator is secure.
• Check condition of belt and wiring.

Operation

Start the engine, then turn on the generator.
See the Miller Generator Technical Manual (PN 3121677) for more
information.
SECTION 6 - ACCESSORIES
6-11