Vega VEGABAR 86 Operating Instructions Manual page 49

Submersible pressure transmitter with ceramic measuring cell
Hide thumbs Also See for VEGABAR 86:
Table of Contents

Advertisement

Failure
Code
Cause
Text message
F013
No valid measured
value available
F017
Adjustment span too
small
F025
Error in the lineari-
zation table
F036
no operable sensor
software
F040
Error in the elec-
tronics
F041
Communication
error
F042
Communication er-
ror Slave
F080
General software
error
F105
Measured value is
determined
F113
Communication
error
F260
Error in the cali-
bration
F261
Error in the instru-
ment settings
VEGABAR 86 • Foundation Fieldbus
This status message is inactive by default. It can be activated by the
user via PACTware/DTM or EDD.
Gauge pressure or low pressure
Measuring cell defective
Adjustment not within specifica-
tion
Index markers are not continu-
ously rising, for example illogi-
cal value pairs
Failed or interrupted software
update
Hardware defect
No connection to the sensor
electronics
No connection to the Slave
General software error
The instrument is still in the
start phase, the measured value
could not yet be determined
Error in the internal instrument
communication
Error in the calibration carried
out in the factory
Error in the EEPROM
Error during setup
Error when carrying out a reset
9 Diagnosis, asset management and service
Rectification
Exchange measuring cell
Send instrument for repair
Change the adjustment accord-
ing to the limit values
Check linearisation table
Delete table/Create new
Repeat software update
Check electronics version
Exchanging the electronics
Send instrument for repair
Exchanging the electronics
Send instrument for repair
Check connection between
sensor and main electronics
(with separate version)
Check connection between
Master and Slave
Disconnect operating voltage
briefly
Wait for the end of the switch-
on phase
Disconnect operating voltage
briefly
Send instrument for repair
Exchanging the electronics
Send instrument for repair
Repeat setup
Repeat reset
DevSpec
Diagnosis Bits
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 13
Bit 28 of Byte 0 ... 5
Bit 5
Bit 6
Bit 12
Bit 8
Bit 9
49

Advertisement

Table of Contents
loading

Table of Contents