Electronics compartment
Connection compartment
VEGABAR 86 • Foundation Fieldbus
Fig. 14: Electronics compartment - double chamber housing
1
Internal connection to the connection compartment
2
Contact pins for the display and adjustment module or interface adapter
3
Simulation switch ("1" = mode for simulation release)
1
Fig. 15: Connection compartment - double chamber housing
1
Voltage supply, signal output
2
For display and adjustment module or interface adapter
3
For external display and adjustment unit
4
Ground terminal for connection of the cable screening
5 Connecting to the bus system
0
Bus
+
1
2
5
6 7 8
( )
(-)
1
1
Bus
+
1
2
5
6 7 8
( )
(-)
2
3
2
3
4
23