Pump Sets 16 Inches And Above - KSB S 100D Booklet

Submersible borehole pumps 60 hz
Hide thumbs Also See for S 100D:
Table of Contents

Advertisement

Applications
Transport of pure and natural water for ...
--
general water procuring and supplying,
--
irrigation and sprinkling,
--
ground-water lowering and maintaining in open-work
mining,
--
water maintaining and draining of galleries in underground
mining.
In addition in pressure-boosting plants and sprinkler
installations as well as in offshore and cavern technologies etc.
Admissible contents of sand in the liquid handled: 50 g/m
Operating Data
Capacity
. . . . . . . . . . . . . . . . . . .
Head
. . . . . . . . . . . . . . . . . . . . . .
Temperature of liquid handled t
Speed
. . . . . . . . . . . . . . . . . . . . .
Design
Single- or multi-stage, single-flow centrifugal pumps in
ring-section design. For vertical, angled and horizontal
installation. Mixed-flow hydraulics with reducibles impellers.
The stage casings are connected by means of studs.
Suction casing between pump and motor with suction strainer
as protection of pump against coarse impurities of the liquid
handled.
Pump end at choice with non-return valve or connection nozzle.
Either design with flanged connection.
Especially suitable for installation in narrow deep wells.
Designation
Type series
Design status
Minimum well diameter (mm)
Suction impeller
Code for hydraulics (50 Hz)
Number of stages
Impellers reduced
1)
X = 400 mm (16 inches), Y = 450 mm (18 inches),
Z = 500 mm (20 inches), E = 600 mm (24 inches),
F = 650 mm (26 inches)
Certification
Quality management certified to ISO 9001
3
Q up to 2200 m
/h (610 l/s
or up to 10,000 US GPM)
H up to 240 m
o
.
up to + 50
C
n ≈ 1750 rpm
B
R
Z S
535 / 5 a
1)
60 Hz
Submersible Borehole Pumps
of 400 mm (16 inches) and Above
3
.
Product Features
-- Very sturdy design
-- Suitable for installation in narrow deep wells
-- High efficiency
-- Motor designed for maximum pump output
-- Low noise level
-- For vertical or horizontal installation
-- Non-return valve protected against blocking
-- Pre-filled motor without risk of contamination of the pumped
water
BSX, BSF
for Well Diameters
single-flow and mixed-flow
87