(10) When assembling Volute case (j) to Engine section, take care while routing Control cable and high voltage cable (m) through the
grooves to ensure that Carburetor gasket (k) is in the position shown in Fig. 61 and Insulator complete (l) fits in the groove. (Fig. 61)
Fig. 61
(l)
Fits in groove
Triangular rib
(11) Attach Muffler gasket (n) so that it is on the muffler side of the rib (o) of Volute case as shown in Fig. 62.
Fig. 62
(n)
(o)
(12) Connect Control cable to Carburetor and connect the lead wire of Stop switch to Ignition coil.
(13) Insert Control cable corrugated tube and the bullet terminal in the storage space of Front volute case. For the specification with a line
filter, also insert Line filter and any slack wire in the storage space. (Fig. 10)
(14) For the tubes for connecting Fuel tank and Carburetor, attach each protector in reference to Fig. 42.