Page 2/2 is added.
DURATION is not didplayed when
REPEAT is INH.
[ Duration and Repeat time for Telemetry Alarm ]
Sensor A
ON
Alarm
OFF
Sensor B
ON
Alarm
OFF
Alarm output
ON
(Buzzer,
OFF
Vibration
, Speech)
DURATION time
REPEAT time
5.SENSOR (Apply to new ESC)
New Robbe's ESC which includes
some sensors is applied.
Sensors : Current, Voltage, Current
capacity, RPM and Temperature
The slot which can be registered : 1, 2, 3,
8,9,10,11,16,17,18,19,24,25,26,27
Using slots : 5 slots
Please refer the instruction manual of T14SG / FX-22 for each setting.
【Setting range】 ↓ THRESHOLD ~ +150.0A
【Setting range】 ↓ THRESHOLD ~ 70.0V
【Setting range】 ↓ THRESHOLD ~ +32,000mAh
【Setting range】 ↓ THRESHOLD ~ 150,000rpm
【Setting range】 ↓ THRESHOLD ~ +100℃
DURATION value have to be
equal or less than REPEAT value.
Time
When the new alarm event
occurs, DURATION time is
extended.
【Setting range】 -150.0A ~↑ THRESHOLD
【Setting range】 0.0V ~↑ THRESHOLD
【Setting range】 -32,000mAh ~↑ THRESHOLD
【Setting range】 0 rpm ~↑ THRESHOLD
【Setting range】 -20℃~↑ THRESHOLD

6.S.BUS SERVO

(SBD-1 CH setting)
CH setting of SBD-1 is available.
■ Please connect the SBD-1 and the battery to S.I/F port with 3 ways
hub or Y harness.
* The battery is not necessary at FX-22. FX-22 outputs the voltage for SBD-1.
■ Please select S.BUS SERVO menu in SYSTEM menu.
■ Please move to page 3/3.
■ Please operate RECALL button. (RECALL is chosen. ⇒ RTN is pushed.
⇒ RTN is pushed for 1 second.) SBD-1 setting screen is shown.
■ Please set CH to each port of SBD-1. (SX1, SX2 and SX3)
* Setting range : CH1 ~ CH12,DG1,DG2
■ Please operate WRITE button. (WRITE is chosen. ⇒ RTN is pushed.
⇒ RTN is pushed for 1 second.)
■ The settings are changed.
■ When the WRITE operation is success, the message "COMPLETED" is
shown.
■ When the WRITE operation is failure, the message "FAILED" is shown.
(S.BUS CH setting)
CH setting of new Robbe's ESC is available.
■ Please connect the ESC to S.I/F port.
* At FX-22, DO NOT connect the ESC to S/I/F directly.Please use 3 ways hub without
battery line. Or, please use the switch for BEC output and turn off the BEC output.
■ Please connect the battry to the ESC.
■ Please select SBUS SERVO menu in SYSTEM menu.
■ Please move to page 3/3.
■ Please operate RECALL button. (RECALL is chosen. ⇒ RTN is pushed.
⇒ RTN is pushed for 1 second.) CH setting screen is shown.
■ Please set CH.
* Setting range : CH1 ~ CH12,DG1,DG2 (ESC does not work in DG1 and DG2.)
■ Please operate WRITE button. (WRITE is chosen. ⇒ RTN is pushed.
⇒ RTN is pushed for 1 second.)
■ The settings are changed.
■ When the WRITE operation is success, the message "COMPLETED" is
shown.
■ When the WRITE operation is failure, the message "FAILED" is shown.
7.S.BUS SERVO (OLP setting)
When the servo type is OLP mode, the torque and time for OLP can be
set. When the load is greater than this setting torque and continues over
this setting time, OLP works.
■ Trq
This is the torque for working OLP.
Setting range : 10% ~ 100% (100% is the maximum torque of the servo which you
are setting.)
■ TIME
This is the time for working OLP.
Setting range : 0.2,0.5,1,2,3,4,5,6,7,8,9,10,15,20,25,30 sec
When TYPE is set to OLP at page 2/3,
OLP trq and time is shown at page
3/3.
*If the setting of OLP torque and time is decreased, it is easier to work OLP.
Then, please be careful not to work OLP at usual operation.
- 5 -
WRITE operation is writing
RECALL operation is reading
CH settings to SBD-1.
CH settings from SBD-1.
RECALL operation is reading
WRITE operation is writing
CH settings to ESC.
CH settings from ESC.
This is the torque for working OLP.
This is the time for working OLP.

Advertisement

loading

This manual is also suitable for:

Fx-22