CLEARANCES DIAGRAM

Vertical clearance of 120" from burner to combustible structure or materials is
required. Horizontal or lateral clearance of 36" between edge of burner and
combustible structure or materials is required.
External power switch
required for all
electronic ignitions
(other than battery
operated ignitions)
2 hr or 12 hr
Dial Timer
(Optional)
EMERGENCY
STOP
PUSH
Emergency
Stop Push
Button
(Optional)
GENERAL INSTALLATION INSTRUCTIONS
Use only joint compound, thread sealant, or tape specific
to gas use that is resistant to all gases. Apply joint
compound, thread sealant or tape to all male pipe fittings
only and DO NOT USE ON FLARED FITTINGS. Be sure to
tighten every joint securely.
Ignition systems are recommended on any burner
over 300K BTUs. If you are lighting manually be sure
to maintain a minimum safe distance to avoid property
damage, personal injury, or death. Please refer to match
lit instructions.
1. Verify gas supply matches burner type.
2. Verify gas inlet pressure is within the specified min-
imum and maximum pressures. Consult Gas Inlet
Pressures on page 6.
3. Purge gas lines of air, water and debris.
4. Perform all leak tests with leak detector or leak reactant
on main gas supply and repair leaks as necessary. Turn
off gas supply.
5. For models that include electronic ignitions, be sure to
8
Clearances
from combustible
structure or
materials
110V\120V
Power Line
36"
Capstone
(A)
(B)
www.Warming-Trends.com | 303 346 2224 | orders@warming-trends.com
Fire Pit Cavity Components
(A) GFCI Outlet
(B) Location for remote receiver (optional)
(C) Pigtail plug included for easy installation
(D) Electronics Box (Houses 120V - 24V Transformer)
(E) 24V Power from Transformer to Gas Valve
(F) Gas Valve / Control Box
(G) Pilot Assembly
(H) Gas Valve Supply IN
(I) Gas Stub from source
CROSSFIRE™
Brass Burner Aluminum
Plate/Pan
(G)
(D)
(F)
(H)
(C)
(E)
(I)
have a qualified electrician install proper power supply
following all local codes.
6. Inspect flex line(s) for punctures or breaks in line(s).
7. Make sure the key turns in the key valve before in-
stalling. Use only your hand to turn the gas key valve.
Never use tools. If the key valve will not turn by hand,
don't try to repair it. Force or attempted repair may
cause a fire or explosion.
8. Refer to Connection Diagrams starting on page 10
for applicable gas connections.
9. Position burner safely with access to all gas connec-
tions for testing.
10. Turn on gas supply to preform repeat leak tests on
main gas supply and all connections to appliance and
repair as needed.
11. Do not use appliance if there is evidence of leaking gas. If
leak is suspected, turn off main gas supply immediately.
For appliances for use with a fixed fuel piping system and
equipped with an appliance gas pressure regulator, the
- Burner and jets should be
covered by up to 1/2" of media
above jets.
- 12 - 13" Minimum clearance
below plate required for
electronic ignition
Enclosure constructed
of all non-combustible
Capstone
materials
Required 18 sq.
inches of venting, or
equivalent, on
OPPOSING sides of
fire pit. (36 inches total.)