Wiring Guidelines 
ELECTRICIAN MUST READ THE FOLLOWING INFORMATION PRIOR TO INSTALLATION. 
Electrical connec ons made improperly, or the use of wire gauge sizes for incurring power which are too small, may          
con nually blow fuses in the electrical equipment support box, may damage the internal electrical controls and                
It is the responsibility of the hot tub spa owner to ensure that electrical connec ons are made by a qualified electrician                 
in accordance with the Na onal Electrical Code and any local and state electrical codes in force at the  me of installa on. 
ALL EQUIPMENT MODELS ARE 120/240 VOLT, 60 CYCLE FOR STATE‐SIDE, U.S. INSTALLATIONS,  
 
 
All hot tubs must be permanently connected.  
 
 
All hot tub support systems are mul ple supply circuits.  
 
 
All hot tub systems require the installa on of a ground fault circuit interrupter (GFCI) protector or equivalent;     
 
(RCD, for export installs), at the power source (NOT SUPPLIED BY PDC SPAS) by a qualified electrician in                    
 
accordance with all codes and regula ons. Refer to typical GFCI installa on photos and illustra ons on the          
 
following pages. 
 
 
Prior to each use, tes ng of the GFCI (or equivalent RCD) is required! Refer to the maintenance sec on of this    
 
manual for instruc ons 
 
 
All hot tub support equipment must be bonded (grounded) to the pressure connector located within the control 
 
support box as well as the outside of the control support box. (see wiring schema c below and references on
following pages) 
 
 
Disconnect all electrical supplies and contact a qualified technician before servicing. 
 
 
All hot tub installa ons are to be performed by a licensed electrician and in accordance with all local and                   
 
na onal codes. 
Hot Tub Wiring Schema c for Cer fied Electricians' Reference Only 
O
 1 
Main Panel 
Circuit Breaker 
G.F.C.I. 
Op on 2 
Main Panel 
Circuit Breaker 
*  Na onal U.S. code recommends distance not to exceed 15  . 
ELECTRICAL REQUIREMENTS 
components, may be unsafe and in any case will void the spa warranty. 
IMPORTANT !! 
AND 50 HZ FOR EXPORT, CE, INSTALLATIONS. 
Wire "A" 
Wire "A" 
 
 
Wire "B" * 
Disconnect 
Wire "B" * 
D
 
G.F.C.I. 
30 
Hot Tub 
Hot Tub 