Electrical Guidelines (60Hz) North America
 
All installa ons and connec ons are to be performed by a qualified, licensed electrician only  
and in accordance with the Na onal electric code and all applicable local regula ons.    
Ensure power is turned off prior to making any electrical connec ons. 
Swim Spa Units must be installed with a Class A 50 Amp Ground Fault Circuit Interrupter (not supplied)
in accordance with the Na onal Electric Code and all applicable local codes.
Installa on of GFCI varies among those manufacturers. Follow each manufacturer's guidelines
to ensure proper opera on and protec on of swim spa occupants.
IMPORTANT:  
GROUND
NEUTRAL
LINE 1
LINE 2
STRAIN RELIEF
Connec ng Power to Swim Spa Pack  (QUALIFIED ELECTRICIAN ONLY) 

Confirm the circuit being used for swim spa power is GFCI protected either
at main panel box or at disconnect.

Verify that power is off to outside disconnect / GFCI.

Determine how wire is to enter swim spa cabinet.

Route wire into swim spa cabinet over to spa pack.

Remove spa pack cover.

Install appropriate strain relief into spa pack. (see photo above)

Insert wire through strain relief, removing wire sheath as needed depending on
wire type.

Strip insula on from wire and insert wire into correct terminal on terminal block.
(see photo above)

Replace spa pack cover.

Refer to start up procedure in manual before turning power on.
FOR QUALIFIED ELECTRICIAN REFERENCE ONLY!  
ATTENTION ELECTRICIAN: 
6 Gauge Copper Wire MUST Be Used 
Test GFCI Monthly and Prior to Each Use. 