ISOLATION PROCEDURE
BINDING OR JUMPY MOVEMENT OF CONTROL WHEEL (Cont).
Cables not routed properly
Check cable routing.
on pulleys.
Defective pulleys or cable
Check pulleys and cable guar
guards.
Defective bearings in elevator
Check bearings.
bellcrank or balance weight
arm.
Defective elevator hinge
Check bearings.
bearings.
Clevis bolts too tight.
Check for binding.
Incorrect rigging.
Check rigging.
Teflon tape too thick in collar
Check thickness of Teflon tape.
on control wheel tube.
ds.
Route cables properly.
Replace defective parts and install
guards properly.
Replace defective bearings.
Replace defective bearings.
Readjust to eliminate binding.
Rig per paragraph 8-5.
Replace . 07" thick Teflon tape
with . 06" thick Teflon tape.
INCORRECT ELEVATOR TRAVEL.
Elevator system incorrectly
Check rigging.
rigged.
Stop bolts improperly positioned.
Check.
Rig in accordance with rigging
procedure.
Reposition stop bolts.