Becker R12/17 C SE+ K8 Assembly And Operating Instructions Manual

Tubular drives for sun protection with automatic cloth untensioning

Advertisement

R12/17...L80/11
Version: C SE+ K8
Assembly and Operating Instructions
en
Tubular drives for sun protection with automatic
cloth untensioning
Important information for:
• Fitters / • Electricians / • Users
Please forward accordingly!
These instructions must be kept safe for future reference.
2010 300 853 0b     24/01/2019   
Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R12/17 C SE+ K8 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Becker R12/17 C SE+ K8

  • Page 1 Tubular drives for sun protection with automatic cloth untensioning Important information for: • Fitters / • Electricians / • Users Please forward accordingly! These instructions must be kept safe for future reference. 2010 300 853 0b     24/01/2019    Becker-Antriebe GmbH Friedrich-Ebert-Straße 2-4 35764 Sinn/Germany www.becker-antriebe.com...
  • Page 2: Table Of Contents

    Table of contents General .................................... 3 Warranty .....................................  3 Safety instructions ................................ 4 Instructions for the user.............................. 4 Instructions for installation and commissioning........................ 4 Intended use .................................. 6 Assembling and disassembling the plug-in connecting cable.................... 6 Assembling the plug-in connecting cable ..........................  6 Disassembling the plug-in connecting cable for tubular drives dia.
  • Page 3: General

    General These tubular drives are high-quality products with the following features: • Optimised for articulated-arm awnings, cassette awnings, drop-arm awnings, screens and conservatory shades. • Easy to set and delete the limit positions using the programming unit • Automatic shading solution length adjustment: Changes in the fabric (temperature, ageing, moisture) are accommodated •...
  • Page 4: Safety Instructions

    Safety instructions The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury. Instructions for the user General information • The drive must be disconnected from its power source during cleaning and maintenance and when re- placing parts.
  • Page 5 • Hazardous moving parts of the drive must be installed at a height of over 2.5 m above floor level or any other surface from which the drive can be accessed. • To ensure safe operation of the system after commissioning, the limit positions must be correctly set/ programmed in.
  • Page 6: Intended Use

    Intended use The type of tubular drive in these instructions is intended exclusively for the operation of articulated-arm awnings, cassette awn- ings, drop-arm awnings, screens and conservatory shades. To function properly, this type of tubular drive needs a fixed stop in the retracted limit position (e.g., retracted awning).
  • Page 7: Disassembling The Plug-In Connecting Cable For Tubular Drives Dia. 45 And Dia. 58

    Disassembling the plug-in connecting cable for tubular drives dia. 45 and dia. 58 Caution Prior to disassembly, the power supply to the connecting cable must be disconnected. Insert a suitable flathead screwdriver right into the recess of the locating latch, so that the latch releases the locating lug from the plug.
  • Page 8: Installation

    Installation Assembling the drive Attention To connect the drive to the driven part, solely mechanical accessory components made by the drive manufacturer from the current product catalogue may be used. Prior to mounting, the fitter must ensure that the masonry and the system being motorised are sufficiently robust (drive torque plus weight of the shading solution).
  • Page 9: Disassembling The Drive Adapter With Safety Catch On The Drive Shaft

    Disassembling the drive adapter with safety catch on the drive shaft Disassembly with disassembly tool, Item no. 4930 300 606 0 Disassembly with long nose pliers Assembling and disassembling the drive adapter with separate drive adapter safety catch Assembling and disassembling the drive adapter with screw connection Mounting the drive in the tube For profile tubes: In the case of some drive adapters, tolerances of the groove widths in different bar-...
  • Page 10 For round shafts: Measure the lug of the thrust ring (X, Y). Then notch the tube on the motor side, so the lug of the thrust ring can also be pushed into the shaft. There must be no play between the lug of the thrust ring and the shaft. To ensure secure torque transmission for round shafts, we recommend screwing the drive adapter to the shaft (see the table below).
  • Page 11: Adjusting The Limit Positions With A Rotary Switch Or A Locking Button

    Adjusting the limit positions with a rotary switch or a locking button Intelligent installation management Limit position status indicator A brief stopping and restarting indicates that no limit position has been set in that direction of movement. Completion of installation following automatic setting of limit position "Stop" The drive saves the limit position "Stop"...
  • Page 12: Setting The Limit Positions Using The Programming Unit

    Setting the limit positions using the programming unit Intelligent installation management Limit position status indicator A brief stopping and restarting indicates that no limit position has been set in that direction of movement. Completion of installation following automatic setting of limit position "Stop" The drive saves the limit position "Stop"...
  • Page 13: Deleting The Limit Positions Using The Programming Unit

    Deleting the limit positions using the programming unit Connect the wires of the tubular drive to those of the same colour in the programming unit and switch on the power supply. Please pause for 1 sec after the last drive command before beginning the deletion se- quence.
  • Page 14: Automatic Adjustment Of Direction Of Rotation

    Deleting both limit positions Any additional functions that may have been set are deleted at the same time, or are reset to the factory default settings. Open/close the shading solution to a point between the limit positions. Press the programming button and keep it pressed. Then press down the travel button and keep it pressed.
  • Page 15: Information For The Electrician

    Information for the electrician Tubular drives with electronic limit switching can be connected in parallel. The maximum switching contact load of the switching equipment (timer, relay control, switch, etc.) must be observed. To operate drives with electronic limit switching, only use switch- ing elements (timers) that are not earthed via the drive.
  • Page 16: Technical Data Dia. 58

    Technical data dia. 58 Type L60/11 L80/11 C SE+ K8 C SE+ K8 Rated torque [Nm] Output speed [rpm] Limit switch range 64 revolutions Supply voltage 230 V AC / 50 Hz Connected load [W] Rated current consumption [A] 1.20 1.40 Operating mode S2 4 min Degree of protection IP 44 Min.
  • Page 17: Sample Wiring Diagram

    Sample wiring diagram The assignment of the black and brown wires according to the direction of travel is de- pendant on how the drive is installed (mounted to the right or to the left). Controlling one/several drive(s) via a single switch/button...
  • Page 18: Declaration Of Conformity

    Declaration of conformity...