7.3.7 VLT
®
MCB 103 Resolver option is used for interfacing resolver
motor feedback to VLT
are used as motor feedback devices for permanent magnet
brushless synchronous motors.
When the resolver option is ordered separately, the kit
includes:
Resolver input option.MCB 103.
Enlarged LCP fixture and enlarged terminal cover.
Selection of parameters: 17-5* Resolver Interface.
MCB 103 Resolver Option supports a various number of
rotor resolver types.
7
7
Resolver poles
Resolver input
voltage
Resolver input
frequency
Transformation ratio Parameter 17-53 Transformation Ratio: 0.1–
Secondary input
voltage
Secondary load
Table 7.11 Resolver Specifications
72
Resolver Input MCB 103
®
AutomationDrive FC 302. Resolvers
Parameter 17-50 Poles: 2 x 2
Parameter 17-51 Input Voltage: 2.0–8.0
7.0
Vrms
Parameter 17-52 Input Frequency: 2–15 kHz
x 10.0 kHz
1.1 x 0.5
Maximum 4
Vrms
Approximately 10 kΩ
Danfoss A/S © 6/2016 All rights reserved.
®
VLT
Parallel Drive Modules
R1
R2
x
Vrms
Resolver
stator
Illustration 7.9 Resolver Input MCB 103 used with a Permanent
Magnet Motor
NOTICE
The MCB 103 can be used with only rotor-supplied
resolver types. Stator-supplied resolvers cannot be used.
LED indicators
The LEDs are active when parameter 17-61 Feedback Signal
Monitoring is set to [1] Warning or [2] Trip.
LED 1 is on when the reference signal is OK to resolver.
LED 2 is on when Cosinus signal is OK from resolver.
LED 3 is on when Sinus signal is OK from resolver.
MCB 103
Option B
Resolver Input
SW. ver. X.XX
Code No.
X32/
1 2
3
4 5
6
7
8
9
10
11
12
1
2
3
4
LED 1 REF OK
LED 2 COS OK
LED 3 SIN OK
LED NA
Rotor
S1
θ
S3
S4
S2
Motor
REF+
R1
REF-
R2
COS+
S1
COS-
S3
SIN+
S2
SIN-
S4
MG37N102