7.3.2 Digital Inputs - Terminal X30/1-4
Digital Input
Number of digital inputs
Terminal number
Logic
Voltage level
Voltage level, logic 0 PNP (GND=0 V)
Voltage level, logic 1 PNP (GND=0 V)
Voltage level, logic 0 NPN (GND=24 V)
Voltage level, logic 1 NPN (GND=24 V)
Maximum voltage on input
Pulse frequency range
Duty cycle, minimum pulse width
Input impedance
7.3.3 Analog Inputs - Terminal X30/11, 12
Analog Input
Number of analog inputs
Terminal number
Modes
Voltage level
Input impedance
Maximum voltage
Resolution for analog inputs
Accuracy of analog inputs
Bandwidth
7.3.4 Digital Outputs - Terminal X30/6, 7
Digital Output
Number of digital outputs
Terminal number
Voltage level at digital/frequency output
Maximum output current
Maximum load
Maximum capacitive load
Minimum output frequency
Maximum output frequency
Accuracy of frequency output
7.3.5 Analog Output - Terminal X30/8
Analog Output
Number of analog outputs
Terminal number
Current range at analog output
Maximum load GND - analog output
Accuracy on analog output
Resolution on analog output
MG37N102
Design Guide
Danfoss A/S © 6/2016 All rights reserved.
18, 19, 27, 29, 32, 33
PNP or NPN
0–24 V DC
>10 V DC
<14 V DC
>19 V DC
28 V continuous
0–110 kHz
53, 54, X30.11, X30.12
-10 V to +10 V
10 bit (+ sign)
Maximum error 0.5% of full scale
®
VLT
AutomationDrive FC 302: 100 Hz
X30.6, X30.7
Maximum error: 0.1% of full scale
0–20 mA
Maximum error: 0.5% of full scale
4 (6)
<5 V DC
4.5 ms
>2 kΩ
7
7
2
Voltage
>10 kΩ
20 V
2
0–24 V
40 mA
≥600 Ω
<10 nF
0 Hz
≤32 kHz
1
42
500 Ω
12 bit