Chapter 5 Wiring - Mitsubishi Electric MELSEC iQ-F Series Reference Manual

Cam output control function block reference
Hide thumbs Also See for MELSEC iQ-F Series:
Table of Contents

Advertisement

5
WIRING
The following shows a wiring example for the iQ-F series programmable controller of Mitsubishi Electric Corporation, an
encoder, and a device.
(2) Absolute encoder
0V
24V
2
0
2
S/S
0V
24V X20 X21
COM4
Y20
Y21
No.
Device
(1)
FX5U(C)CPU
(2)
Absolute encoder
(3)
Device controlled by cam output FB
*1 When the filter is used in the input terminal, one-fourth of the constant is added as the difference (delay). Set the input response time
(digital filter setting value) to "None". For the setting method, refer to MELSEC iQ-F FX5 User's Manual (Application).
Gray code signal, etc.
1
2
2
2
3
2
4
2
5
2
6
2
7
2
8
2
X22
X23
X24
X25
X26
X27
X30
X31
(3) Device controlled
by cam output FB
Remarks
The input number of X20 or later and output number of Y20 or later are recommended.
Resolution: 2048
Output format: sink output
9
2
10
X32
(1) FX5UCPU
Y76
Y77
5
*1
5 WIRING
29