1.3 Device overview

.
Fig. 1
3:
1. Explosion-protection warning information
2. Warning information for electricity
3. Name plate

1.4 Explosion marking as per EC type examination

Explosion marking:
EC type examination:
Ambient temperature:

1.5 Marking as per the IECEx scheme

IECEx marking and data provisional.
Explosion marking:
IECEx certificate (CoC):
Ambient temperature:

1.6 Voltage supply

Voltage:
Power consumption:
Protection class:
IP rating:
Markings and warning information
BVS 19 ATEX 012 X
–10°C ≤ T
Ex pxb IIC T4 Gb
BVS 19.0000X
–10°C ≤ T
230 volts or 115 volts, 50/60 Hz alternating current
185 VA max.
I
IP44
II 2G Ex pxb IIC T4 Gb
≤ +50°C
amb
≤ +50°C
amb
Technical data
1
2
3
7