Special Notes on Installation
IMPORTANT
Avoid overloading by positive pressure difference between delivery side and intake side:
•
Install end of delivery line higher than the liquid level in the intake tank.
or:
•
Install the discharge line outlet of the pump such that its position is higher than the
level of liquid in the chemical storage tank
or:
•
Install pressure control valves in the pump delivery line.
IMPORTANT
Ensure constant pressure in the intake line!
Irregular pump flow can occur if the pressure from the take-off line or the intake tank
is transmitted.
•
Ensure constant supply height when pump intake is from pressurized lines!
•
Ensure constant supply level if intake is from high supply level!