AT+FBADLIN
Description:
Set command:
Possible set command
responses:
Read command:
Test command:
Test command
response:
Parameter:
<value>:
AT+FBADMUL
Description:
Set command:
Read command:
Test command:
Test command
response:
Parameter:
<value>:
91
93
94
100
101
102
103
120-255
Bad Line Threshold
Sets the maximum acceptable consecutive number of bad lines.
AT+FBADLIN=<value>
Copy Quality OK.
Copy Quality Not OK.
AT+FBADLIN? Displays the current <value> setting.
AT+FBADLIN=? Shows if the command is supported.
+FBADLIN: (list of supported <value>s)
<value>
0
Error Threshold Multiplier
Sets the maximum acceptable percentage of bad lines per page multiplication value.
AT+FBADMUL=[<value>]
AT+FBADMUL? Displays the current <value> setting.
AT+FBADMUL=? Shows if the command is supported.
+FBADMUL: (list of supported <value>s)
<value>
0
20
0-255
Missing EOL after 5 seconds
TAE to TE buffer overflow
Bad CRC or frame (ECM or BFT modes)
Unspecified Receive Phase D errors
RSPREC invalid response received
COMREC invalid response received
Unable to continue after PIN or PIP
-reserved codes-
Description
Error checking not present, or disabled
Default setting
Description
Error checking not present, or disabled
Default setting
Corresponds to a 5% error rate