8
Fully charge the leisure area battery before closing down the system.
"
Switch off the 12V main switch on the control panel.
"
Move battery cut-out switch (switch, see Fig. 4, Pos. 5) to position "Bat-
"
tery OFF".
The battery cut-out switch isolates the following connections from the leisure
area battery:
12V consumers
F
Frost protection valve
F
Operator and control panel
F
Remove the step fuse (refer to Fig. 4, Pos. 6) on the electroblock
"
For vehicles with AES refrigerator:
"
Remove the AES fuse (refer to Fig. 4, Pos. 3) on the electroblock
The battery alarm is no longer active.
Y
The frost protection valve opens for certain heater systems when the lei-
sure area battery is isolated from the electroblock via the battery cut-out.
The boiler and water tank empty when the frost protection valve is open.
See the instruction manual for the heater system for further information.
The leisure area battery is also charged by the internal charger module,
an additional battery-charger, the solar charger regulator and the alterna-
tor when the battery cut-out is activated.
Cancelling the shutdown
Move battery cut-out switch (switch, see Fig. 4, Pos. 5) to position "Bat-
"
tery ON".
Insert the step fuse (refer to Fig. 4, Pos. 6) on the electroblock
"
For vehicles with AES refrigerator:
"
Insert the 15A AES fuse (refer to Fig. 4, Pos. 3) on the electroblock
After having disconnected the leisure area battery from the electroblock
"
using the battery cut-off switch or after changing the battery, briefly
switch on the 12 V main switch on the control and switch panel to start up
the consumers.