Input Registers (3X References); Reference Values For Selecting A Standard Mapping In Accordance With The Operating Values Of The Primary Equipment - Siemens SIPROTEC 7SJ61 Technical Data Manual

Multifunction protection with control
Hide thumbs Also See for SIPROTEC 7SJ61:
Table of Contents

Advertisement

6.5

Input registers (3X references)

Standard mapping
6.5.1 Reference values for selecting a standard mapping in accordance with
the operating values of the primary equipment
Standard
Parameter address 1101
mapping
Primary operating voltage
no.
V
prim
1
1,0 kV ... 327.67 kV
2
1,0 kV ... 32.76 kV
3
1,0 kV ... 32.76 kV
Standard
Parameter address 206
mapping
Ratio factor
no.
V
/ V
ph
1
V
* V
/ V
prim
ph
delta
2
V
* V
/ V
prim
ph
delta
3
V
* V
/ V
prim
ph
delta
7SJ61/62/63 6MD63 - Modbus
C53000-L1840-C001-01
The input register block allows the Modbus master to read the values of
the the analog inputs of the SIPROTEC device (recorded measured
values).
Note
Depending on the device composition not all of the indicated analog
inputs (and corresponding Modbus registers) may be available in the
SIPROTEC device.
Ref. to chap. 5.3 for data type definition of measured values.
By selecting the standard mappings (standard mapping 1 to standard
mapping 3) the measured values can be scaled in accordance with the
operational values of the primary equipment.
For each measured value the table in chap. 6.5.2 shows in the column
"Scaling" the scaling values defined in standard mappings 1 to 3, e.g.
(for "IA ="):
1: 3276.7 A
2: 3276.7 A
3: 32.767 kA
Note
All conditions in the table below to the selected standard mapping must
be fulfilled so that the measured values are transferred correctly via
Modbus.
Dependent on the SIPROTEC device either parameter address 207 or
parameter address 208 is adjustably.
Parameter address 1102
Primary operating current
10 A ... 999 A
1 kA ... 32 kA
10 A ... 999 A
Parameter address 207
Ratio factor
delta
< 327.67 kV
I
* I
/ I
prim
N
ph
< 32.76 kV
I
* I
/ I
prim
N
ph
< 32.76 kV
I
* I
/ I
prim
N
ph
- applies to standard mapping 1
- applies to standard mapping 2
- applies to standard mapping 3
I
prim
I
* V
prim
1 MW <= I
I
* V
prim
I
/ I
N
ph
< 1 kA
I
* I
prim
>= 1 kA
I
* I
prim
< 1 kA
I
* I
prim
Modbus register map
Energy values of the
primary equipment
*
3 >= 1 MW
prim
* V
*
3 < 1 GW
prim
prim
*
3 < 1 MW
prim
Parameter address 208
Ratio factor
I
/ I
Ns
ph
/ I
< 1 kA
Ns
ph
/ I
< 1 kA
Ns
ph
/ I
< 1 kA
Ns
ph
6-23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Siprotec 7sj62Siprotec 7sj63Siprotec 6md63

Table of Contents