Billy Goat F1801V Owner's Manual

Force blower

Advertisement

Quick Links

Accessories
Part No 440179
FORCE BLOWER 18 Owner's Manual
Patent #6,253,416 and other patents pending
BILLY GOAT FORCE BLOWER
Owner's Manual
HOLD DOWN KIT
To secure blower for
transportation on
trailer floors.
P/N 440120
F1801V
PARKING BRAKE
Effective and Easy to
use to prevent blower
from rolling.
P/N 440140
1
Form No F011509B

Advertisement

Table of Contents
loading

Summary of Contents for Billy Goat F1801V

  • Page 1 Patent #6,253,416 and other patents pending BILLY GOAT FORCE BLOWER Accessories HOLD DOWN KIT To secure blower for transportation on trailer floors. P/N 440120 Part No 440179 FORCE BLOWER 18 Owner’s Manual F1801V Owner's Manual PARKING BRAKE Effective and Easy to use to prevent blower from rolling.
  • Page 2: Table Of Contents

    This manual provides complete operating and maintenance instructions that will help to maintain your FORCE Blower in top running order. Read this manual carefully before assembling, operating, or servicing your equipment.
  • Page 3: Serial Plate Data And Specifications

    In compliance with 2000/14/EEC standards Sound at Operator’s ears Vibration at operator position Part No 440179 FORCE BLOWER 18 Owner’s Manual B & S VANGUARD F1801V 18 HP (13.42kW) 3564420224E9 9 qt. (8.52L) 1.75 qt. (1.66L) 179 # (81.2Kg) 58"(1.43m) 29.25”...
  • Page 4: General Safety

    This symbol indicates that this manual and the engine manufacturer’s manual should be read carefully before assembling, operation, or servicing this equipment. This symbol indicates important information that will prevent damage to your BILLY GOAT FORCE Blower. This symbol indicates the engine oil level should be checked before operating this equipment.
  • Page 5 FORCE BLOWER 18 Owner’s Manual DO NOT run this equipment indoors or in any poorly ventilated area. Refueling outdoors is recommended. DO NOT refuel this equipment while the engine is running. Allow engine to cool for at least two minutes before refueling.
  • Page 6: Sound And Vibration

    FORCE BLOWER Owner’s Manual SOUND 117 dB Sound tests were conducted in accordance with 2000/14/EC, as well as ISO 11094, and were performed on 12-12- 2006 under the conditions listed below. Sound power level listed is the highest value for any model covered in this manual. Please refer to serial plate on the unit for the sound power level for your model.
  • Page 7: Instruction Labels

    FORCE BLOWER 18 Owner’s Manual INSTRUCTION LABELS ® The labels shown below were installed on your BILLY GOAT FORCE Blower. If any labels are damaged or missing, replace them before operating this equipment. Item numbers from the Illustrated Parts List and part numbers are provided for convenience in ordering replacement labels.
  • Page 8: Packing Checklist

    ® Your BILLY GOAT FORCE Blower was shipped in one carton, completely assembled except for the Upper Handle Assembly and Front Diverter. Mounting hardware for the Upper Handle Assembly can be found in the parts bag. READ all safety instructions before assembling unit.
  • Page 9: Assembly

    Two ½” open ended wrenches Part No 440179 FORCE BLOWER 18 Owner’s Manual Figure B The throttle control and Aim-and-Shoot to the throttle arm on the engine and wrapped around the engine for shipping.
  • Page 10: Operation

    Never lift the machine while the engine is running. BLOWING OPERATION Your Billy Goat Force blower is equipped with an air director cone and the patented Aim-and-Shoot control lever to allow the operator to direct the air stream up or down as required to assist in moving debris. This feature is extremely useful when debris has piled up to the point that it cannot be blown any farther.
  • Page 11 FORCE BLOWER 18 Owner’s Manual ADJUSTING AIR DIRECTOR To adjust air direction, squeeze Aim-N-Shoot control lever. When you want to blow debris at the same angle for an extended period, choose a suitable position and use the finger controlled push button lock to lock the cone in position.
  • Page 12: Maintenance

    (step 6). 5. If the impeller does not loosen, obtain a 3/4-16x3” (Billy Goat part #440192) or longer bolt. Thread bolt by hand into nut until bolt rests against the shaft. Tighten the bolt slowly, which will pull the impeller away from the shaft, remove impeller from shaft.
  • Page 13: Troubleshooting And Warranty Procedure

    Warranty Claim. • The distributor service manager will sign off on the claim and submit it to BILLY GOAT for consideration. • The Technical Service Department at BILLY GOAT will study the claim and may request parts to be returned for examination.
  • Page 14: Illustrated Parts List

    FORCE BLOWER Owner’s Manual ILLUSTRATED PARTS LIST Part No 440179 Form No F011509B...
  • Page 15: Parts List

    F O R C E W H E E L B E A R I N G Part No 440179 FORCE BLOWER 18 Owner’s Manual 1 / 4 P L A S T I T E # 6 - 1 9 X 5 / 8 "...
  • Page 16: Maintenance Record

    FORCE BLOWER Owner’s Manual MAINTENANCE RECORD Date Service Performed Part No 440179 Form No F011509B...

Table of Contents