Back View - Bticino 343100 Installer Manual

Monobloc audio digital entrance panel
Table of Contents

Advertisement

2.3

Back view

P
N
T S
(*)
T
0
1
2
3
4
5
4 s 1 s 2 s 3 s 4 s 6 s 8 s 10 s
1 - Microphone volume adjustment.
2 - Loudspeaker volume adjustment.
3 - Configurator socket:
P = Entrance panel address (0 – 95)
N = Address of the first called internal unit (0 – 99)
T = Door lock control timer (see table*)
S = Select the ringtone;
S = 0, 1, 2, 3 on the basis of the selection, the internal units ring with a different tone/tune
(Useful to differentiate several entrance panels on the same system);
S = 4, 5, 6, 7 on the basis of the selection, the internal units ring with a different tone/
tune (Useful to differentiate several entrance panels on the same system) and the recall
function (a series of 3 rings for each single call) is activated
4 - J2: remove to disable the sounds.
5 - J1: remove to enable the additional power supply.
6 - Connection to the BTicino 2 wire digital system BUS.
7 - Additional power supply connector.
8 - Door lock additional pushbutton connector.
9 - Door lock contacts connector.
5
4
3
2
1
6
7
Digital Entrance Panel
J2
J1
BUS
1 2 C NO NC PL
P P N
N T S
Monobloc Audio
6
7
8
9
7

Hide quick links: