II. AC lightning protection box
The box helps to realize the ligtning protection for the AC input power of BTS. In terms
of varied discharging currents of the box, it can be classfied into three types 20kA, 40kA
and 100kA. In this manual, all AC lightning protection boxes are of 20kA type.
III. UPS
It is recommended to adopt no-wind UPS with the battery voltage 72V. The packing of
UPS is sunshine-proof, waterproof and moistureproof, so the UPS can operate in
outdoor environment.
IV. IABB
The backup power battery groups of BTS can be placed in the IABB safely satisfying
the backup power supply requirement of the BTS. The box structure is similar to that of
IAFB.

2.1.4 Installation Mode

In terms of environment, the BTS can be installed in the following modes:
Indoor installation
l
Outdoor installation
l
In terms of conditions, the BTS can be installed in the following modes:
Wall installation (Installing BTS on wall)
l
Plinth installation (Installing BTS on plinth)
l
Pole installation (Installing BTS on pole)
l
Metal mast installation (Installing BTS on metal mast)
l

2.1.5 Installation Flow

Installation flow is almost the same no matter which mode is adopted.
Figure 2-2 shows the installation flow of BTS hardware system.
2-3
Hardware Installation
2 Installing Cabinet Hardware